Krix Tektonix Owner'S Manual Download Page 5

In place of conventional mechanical 
potentiometers the signal processor 
utilises Microchip® laser trimmed digital 
potentiometers, this offers precision adjustment 
of volume and filter controls, as well as 
eliminating noise, distortion and reliability 
issues associated with conventional pots.
This all analogue signal path features only high 
quality plastic film coupling capacitors and 
JFET operational amplifiers for stable low noise 
audio performance.

All aspects of the signal processor, including 
fault and monitoring signals, are under 
the control of a Microchip® PIC16F690 
microcontroller, which is commanded from the 
front control panel via a high reliability balanced 
RS485 serial data link. The front control 
panel has its own PIC16F690 microcontroller 
dedicated to managing the LCD display and 
user interface.

high performance driver

The Tektonix and Volcanix both feature high 
power long throw low frequency drivers. Both 
units incorporate a 50mm four layer voice coil 
and motor system optimised for low distortion 
at extreme sound pressure levels. 

5

controls and features

Krix Tektonix and Volcanix innovation

front panel controls

Unlike conventional subwoofers with hard to 
reach rear controls, the Tektonix and Volcanix 
feature a front panel with precision digital 
adjustment. There is no longer any need to pull 
your subwoofer out of a cabinet or away from 
a wall to set up your system, all functionality 
is accessible via the front panel interface. The 
front panel display is backlit to aid viewing in 
low light conditions. After 45 seconds of button 
inactivity the display will return to the volume 
menu and the backlight will fade out.

ICEpower® amplification

Your subwoofer is powered by a low distortion 
ICEpower® amplifier designed by Bang & 
Olufsen ICEpower a/s. This high efficiency 
Class-D amplifier generates far less heat than 
conventional amplifiers and therefore requires 
no bulky external heatsinking. A high-current 
switch-mode power-supply ensures full 
power can be delivered for sustained periods, 
producing maximum dynamics and impact from 
your subwoofer.

signal processor

The Tektonix and Volcanix subwoofers feature a 
high integrity signal processor through the use 
of analogue control stages that form a short 
and direct connection from the input terminals 
to the ICEpower® amplifier, whilst still allowing 
maximum control over the incoming audio 
signal.

symmetrix vent  

Enclosures feature Symmetrix bass reflex 
venting, with the vent exhibiting the same flare 
radius internally and externally. This lowers 
subwoofer distortion and serves to reduce vent 
turbulence or “chuffing” at high drive levels. 

clipping protection 

The ICEpower® amplifier features sound 
optimised soft clipping protection and will 
accurately amplify the input signal to full power 
without compression or loss of dynamics. If an 
input signal is applied beyond the ICEpower® 
amplifiers maximum power limit, soft limiting 
will minimise distortion and protect the 
loudspeaker driver.

fault protection 

Subwoofer amplifiers feature comprehensive 
protection systems that will protect the 
amplifier and loudspeaker from a range of 
possible fault conditions.

The microcontroller constantly monitors the 
ICEpower® amplifier module for possible over- 
temperature and over-current events, as well 
as checking that the AC mains supply is not too 
low for proper operation.

If any of these fault conditions occur, the 
amplifier will immediately be disabled to 
prevent any permanent damage from occurring. 
After the fault condition clears, the unit will 
resume normal operation. Please see the 
troubleshooting guide on page 10 for further 
information. 

feet 

The Tektonix and Volcanix both feature soft 
rubber feet to stop unwanted vibration being 
transmitted into the floor.

Volume 
-30dB

Summary of Contents for Tektonix

Page 1: ...Owner s Manual Tektonix and Volcanix ...

Page 2: ... on the back of this manual before you plug in your equipment Disclaimer To the extent permissible by law 1 All warranties conditions representations promises and statements relating howsoever to this product whether express or implied and whether in contract or tort are excluded to the extent permitted by law and 2 Our liability to you under a condition or warranty if any implied into this sale a...

Page 3: ...5 minutes the subwoofer will switch into standby if no signal is present When set to 12V trigger the subwoofer will switch on from standby when 12V is applied to the trigger input on the rear panel of your subwoofer This allows the subwoofer to switch between on and standby in perfect synchronisation with an AV amp receiver equipped with a trigger output Auto Sensitivity Adjusts the subwoofers swi...

Page 4: ...o an AV amp receiver equipped with a trigger output 5 15V DC or AC may be used to trigger the subwoofer polarity is not critical line in Line level stereo input with summing function high level inputs High level inputs with summing function for use with amplifier speaker outputs power switch and socket Unit should be switched off when not in use for extended periods 4 controls and features ...

Page 5: ...his high efficiency Class D amplifier generates far less heat than conventional amplifiers and therefore requires no bulky external heatsinking A high current switch mode power supply ensures full power can be delivered for sustained periods producing maximum dynamics and impact from your subwoofer signal processor The Tektonix and Volcanix subwoofers feature a high integrity signal processor thro...

Page 6: ... to localise Therefore it may be harder to integrate the sound of your subwoofer with your main speakers D Placing your subwoofer away from your walls can result in satisfying results but maximum output from your subwoofer may be reduced E Subwoofers may also be placed inside cabinetry Please refer to the link on the subwoofer page of the Krix website for suggestions The subwoofer is not magnetica...

Page 7: ...iver is smaller than 5 1 4 use a higher setting 100Hz 120Hz 150Hz to send more of the bass information to your subwoofer Consult your receiver manual for further bass management options and settings manual subwoofer calibration When using the subwoofer in a home theatre installation it is beneficial to listen to movies with extended periods of low bass explosions rumbles etc This will allow you to...

Page 8: ...ss You may need to listen to a variety of recordings to hear any subtle change in bass energy If no change in bass energy can be heard between phase settings set phase to 0 default position Re adjust volume if necessary You may wish to fine tune the crossover frequency low pass setting This will vary the amount of overlap from the subwoofer to the main speakers and increase or decrease the level a...

Page 9: ... connection Using multiple subwoofers can be useful in large or troublesome installations where more uniform bass coverage is desired If your receiver has only one subwoofer output use a RCA Y connector to connect both subwoofer L LFE inputs to the one mono SUB output left and right subwoofers stereo connection If your receiver has stereo line level subwoofer outputs a left and right subwoofer may...

Page 10: ... amp receiver for subwoofer setup procedure Check trigger cable connection and then refer to AV amp receiver for trigger setup procedure Turn subwoofer mains power off and on If problem persists contact your Krix retailer or Krix directly Check power switch is set to I Check mains outlet is suppling power using another appliance e g lamp If problem persists contact your Krix retailer or Krix direc...

Page 11: ...year warranty applies to the amplifier and related internal electronics Refer to the details on the warranty card supplied queries If you have any queries regarding the Tektonix or Volcanix setup procedure or any other Krix product please contact your nearest Krix retailer or Krix directly Contact details are on the back cover of this booklet Tektonix specifications Drivers Bass Driver Electronics...

Page 12: ...materials Do not place unit against curtains or furnishings This equipment is heavy To avoid injury to persons Be careful when you lift the unit Install the unit on the ground so that it cannot fall onto anyone This equipment can cause extreme vibrations To avoid injury to persons fire or damage to the unit Do not put the unit near things that might be damaged by vibration Do not put the unit near...

Reviews: