KREMLIN REXSON
Page 28
Manual : 573.199.112
MATERIAL
FAULTS
CHECKINGS
No fluid flows when passing into production or
flushing mode.
Check if the valves are open :
No
: - Check air supply (minimum 4 bar / 58 psi),
- Check the connection of the 25 pts cable,
- Check the correct operating of the
electrovalves.
Yes
: - Check the fluid pressure,
- Check the static mixer.
The machine displays the correct mixing but the
consumption of catalyst is too important.
Check the grounds of the machine (230V intake and
ground cable of the fluid module)
The machine displays the correct mixing but the
consumption of catalyst is not enough.
Check the grounds of the machine.
When the main menu page is displayed, fluid flows
out when the gun is open.
Check the valves
Checking of the valve : look at what is flowing
-if it is solvent, change the valve (VP1)
-if it is base, change the valve (VP2A)
-if it is catalyst, change the valve (VP2B)
12. PROPORTION AND OUTPUT ACCORDING TO THE RATIO
Ratio (%)
Catalyst proportion (cc)
Maximum output (cc/mn)
5
2,40
500
10
2,40
1000
15
2,40
1000
20
2,40
1500
30
4,80
2000
50
4,80
2000
60
6,10
2000
100
10
2000