OPERATION TO CARRY OUT
FREQUENCY
D
W
M
Q
H
Y
FLUID SECTION
Check the tightness of the cup
X
Check
if
there
is
lubricant
in
the
cupel
(keep the level halfway up)
X
Disassemble the fluid section, clean the parts with the
appropriate cleaning solvent, change the seals and
the parts if necessary
X
Change the lubricant if the coloration is too important
and change the seals of the upper flange if the
problem persists
X
Clean regularly the cup with lubricant after having
drained the lubricant
X
D : daily
W : weekly
M : monthly
Q : quarterly
H : half-yearly
Y : yearly
N ote : F req uencies are g iv en as a clu e. T h ey must b e adapted by the maint en an ce
service of th e user fo r ev ery i nstall ati on acco rdin g to th e p rod uct, th e w orking cad en ce
and th e w o rki ng pressure.