PUMP SEPARATION / COUPLING PROCEDURE
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards.
To work on the pump, it requires to :
- Disassemble all the accessories of the pump (air inlet supply, rods, filter), if necessary.
- Put aside the pump, if necessary (the pump is fitted with an hoisting ring).
Separate the pump
- Stop the pump.
- Disconnect the pump air inlet.
- Remove the screw (12) from the pump
bracket (11) and remove the washer (13).
- Remove the screws (5) from the coupling
housing (4).
- Remove the coupling housings (4).
- Remove the pin (9) and the axis (8).
- Loosen the 4 screws (17) from the outlet
flange.
- Slightly rotate the outlet flange counter
clockwise.
- Separate the fluid section.
Coupling the pump
- Install the fluid section (2) at the 4 screws
(17) level.
- Slightly rotate the outlet flange clockwise.
- Tigthen the 4 screws (17).
- Apply grease (grease, model A1) on the
axis (8) and install it in its housing.
- Install the pin (9) in the axis (8).
- Clip the coupling housings (4).
- Tighten the screw (5) of the coupling
housing.
- Tighten the screw (12) of the pump
bracket.
Summary of Contents for EOS 15-C50
Page 19: ...KREMLIN REXSON 2 N 578 208 110 1502 2 D D x 2 x 2 1 2 ...
Page 24: ...KREMLIN REXSON 2 N 578 048 110 1009 2 3 A B C D ...
Page 25: ...KREMLIN REXSON 3 N 578 048 110 1009 4 ...
Page 27: ...KREMLIN REXSON 2 N 578 062 110 1109 4 2 3 x 2 ...
Page 28: ...KREMLIN REXSON 3 N 578 062 110 1109 5 6 ...
Page 66: ...KREMLIN REXSON 5 N 578 088 120 UK 1605 Ind mm I 72 2 8 Ind mm I 72 2 8 I J ...