n
Always observe the applicable country-specific safety, accident prevention, occupational
safety, and environmental protection regulations for the area of use for the automatic spray
gun.
n
Do not use sharply abrasive, chemically aggressive, very hot or very cold spray media without
first consulting with and receiving approval from Krautzberger GmbH.
n
Adhere to the spray media manufacturer's safety data sheets.
n
Only operate the automatic spray gun while adhering to the values specified in the
(
Chapter 12 ‘Technical data’ on page 41
n
Only operate the automatic spray gun after proper fastening on a suitable carrier design.
n
Do not hold the automatic spray gun in your hand during operation.
n
Never point the compressed air at living beings.
n
Adhere to the operating manuals for the respective components
6.2
Operation
To achieve optimal results, adhere to the following:
–
Rinse the automatic spray gun with cleaning products before commissioning.
–
Too-high air pressure causes unnecessarily high air consumption and too-strong atomi-
sation of the spray fluid.
–
Too-low air pressure produces an unsatisfactory spray pattern.
–
Select the lowest possible fluid pressure.
1.
Make sure that the control air and atomisation air connections are not reversed.
2.
Close the control air (connection "St").
3.
"Open" fluid feed.
Depending on the type of fluid feed, the "opening" of the fluid feed is carried out
–
By opening the connection tap
–
By applying pressure to the storage container
–
By filling the fluid into a storage container (hydrostatic inherent pressure).
4.
Open the control air.
ð
The fluid is sprayed. Generally, the adjustment of the spray pattern is now required
(
Chapter 6.3 ‘Adjusting the spray pattern’ on page 22
).
Automatic spray gun A-14
ENGLISH
■
200-0151
GB–21