8.5 Changing the fluid needle
Disassembly
1.
Chapter 7.5 ‘Shutting down’ on page 24
).
2.
If necessary, secure fluid pressure pump or pressurised fluid container for the spray media
against restart.
3.
Interrupt the external material supply.
Fig. 8: Removing the fluid needle
4.
To reduce the pre-tensioning of the spring ( Fig. 8/2), unscrew the needle stroke adjustment
screw ( Fig. 8/4) on the locking piece ( Fig. 8/3) to the end stop.
5.
Unscrew the locking piece ( Fig. 8/3) with a fork wrench.
6.
CAUTION!
Risk of injury due to fluid needles!
Remove the spring ( Fig. 8/2) and the fluid needle ( Fig. 8/1).
Fig. 9: Fluid needle