background image

Do not use a power source exceeding
the machine’s specified value, only use
220V AC power!

The outlet used for the machine’s
current must be greater than the
machine’s   specified   value;
otherwise   it   may   lead   to
overheating or fire.

When installing or repairing, the machine
must   be   disconnected   from   the   power
source!

Otherwise   it   may   lead   to   electric
shock.

Do   not   damage   the   power   cord   or

outlet!

Doing   so   may   lead   to   electric
shock, short circuiting, or fire.

Do   not   touch   the   power   plug   with   wet

hands!

It may lead to electric shock.

Notes

-4-

Do   not   use   the   water

purifier when the sewer is blocked up!

If it is used while the sewer is

blocked,   it   may   cause   the
waste   water   to   back   up   or

pollution   to   get   inside   the
water purifier.

The   waste   water   discharge

pipe and waste water ratio device cannot
be blocked!

When   the   waste   water   discharge   pipes   and   waste
water ratio device are clogged, it may lead to high TDS

effluent,   the   RO   membrane   may   get   blocked   or   the
water purifier may not work.

Water   purifier   inlet

water   temperature   should   not   exceed
38 !

If   the  inlet  water  temperature  is  over  38 ,  it  will

damage the reverse osmosis membrane leading to

membrane failure.

Do not use in conditions under 5 !

If the temperature in the room is below 5 , please be

sure   to   take   measures   to   prevent   freezing,   such   as

starting the heater or air conditioner to prevent leakage
or cracked pipes caused from water freezing inside the

machine.

Do not use this water purifier outdoors!

If   this   water   purifier   is   used

outdoors,   it   can   lead   to
accelerated aging of the water

purifier  pipes  and  parts,  which
can   cause   leaking   or  machine

failure.

Do   not   use   the   water
purifier in direct sunlight!

When   the   water   purifier   is   in

sunlight for a period of time, it may
create   a   breeding   ground   for

microorganisms   so   the   water
purifier water quality will decrease,

and   they   may   pollute   the   internal

components of the water purifier.

Summary of Contents for NEW LINE A

Page 1: ...ter that can be consumed directly so the water you drink is cleaner and also beneficial to your health Before you install and use this water purifier please be sure to read the user manual this enable...

Page 2: ...Installation Preparations 12 2 Instructions for Proper Installation 13 3 Installation Notes 13 Testing Methods 16 Usage Methods 17 Maintenance and Upkeep 17 1 Filter Replacement Time 17 2 Filter Repla...

Page 3: ...not put heavy objects on the water purifier If heavy objects are placed on the water purifier it may result in damage to the water purifier s dust cover or internal components which could lead to leak...

Page 4: ...waste water ratio device are clogged it may lead to high TDS effluent the RO membrane may get blocked or the water purifier may not work Water purifier inlet water temperature should not exceed 38 If...

Page 5: ...ed disassembly or modification of the machine could lead to machine malfunctions and leakage accidents For example the system s pump type D cannot be installed on the system model A B or C In this cas...

Page 6: ...ction 1 Blown up profile of the water purifier The system could be in 2 versions based on normal bracket or stable bracket Normal Bracket Stable Bracket with Pressure meter Diagram 1 2 Electrical diag...

Page 7: ...s per day Model NAME NEW LINE A NEW LINE A NEW LINE B NEW LINE B NEW LINE C NEW LINE C NEW LINE D NEW LINE D Voltage AC 220 240 V 50HZ 24V 1 8A AC 220 240 V 50HZ 24V 2 2A AC 220 240 V 50HZ 36V 1 5A AC...

Page 8: ...ype II Type II Hardness level max mg ekv lit 8 8 8 8 8 8 8 8 MAX pure water flow per day Lit 40 40 40 40 80 80 120 140 120 140 Notes Due to product improvements the above parameters may change but the...

Page 9: ...e RO membrane Flow Restrictor Waste Water Ratio Device controls waste water flow Low Voltage Switch To prevent pump idling When the inlet water pressure is less than 0 03 MPa or when the inlet water s...

Page 10: ...ately after long work period of time The limit time of flashing could be between 0 5 1 5 min the light is on when the drinking goose neck faucet closed The light is on when the machine purify the wate...

Page 11: ...close machine will flush membrane 30 seconds The pump and inlet solenoid and flush solenoid are all off The buzzer will beep 10 times Full Function 1 If the high pressure switch is open and the machi...

Page 12: ...same time the machine is producing water This design solves the contamination problem such as odours bacteria etc caused by long time pure water storage in tank It supplies the real pure and fresh wa...

Page 13: ...box wrap one end of the ball valve external threads with the appropriate Teflon tape See Diagram 5 if you have silica gel spread a little on and then screw the ball valve into the corresponding hole...

Page 14: ...Take the first RO membrane from its packaging put the end of the membrane with the O ring into the reverse osmosis membrane shell See Diagram 9 and push it in finally screw the membrane shell cover ba...

Page 15: ...brane components the membrane manufacturer does not assume responsibility for returned components due to damage during installation Damage to the membrane shell and reverse osmosis membrane element ca...

Page 16: ...ter will start to drain through the discharge outlet 2 Wait for the water purifier to operate stably about 5 10 seconds check each connection to make sure it is secure see if there is any leakage from...

Page 17: ...ty and utilisation rate and the average indicators there will be more obvious differences between the filter s actual use time and the estimated cycle such as premature filter clogging premature failu...

Page 18: ...ce the filter inside the filter cartridge use the wrench to tighten the filter cover For replacement of membrane elements please see RO Membrane Installation Page 8 3 Notes RO membrane water productio...

Page 19: ...easure the output voltage replace The high pressure pump is working properly but no water is being produced High pressure pump has lost pressure Measure the water pump pressure replace Inlet water sol...

Page 20: ...s the final explanation rights if this manual is unclear has mistakes or if there were printing problems which caused problems Packing List Main machine including 2 units of RO membranes 1 unit Water...

Reviews: