background image

Installation and User Manual  

    Model

s:

 

KRAUSEN NEW LINE A-D LCD    

For indoor use only

Dear customer,

Thank you for purchasing our company’s water purifier!
You   now   have   water   treatment   equipment   that   is   at   the   world’s   leading   position   in   today’s   water

treatment field. It produces pure water that can be consumed directly so the water you drink is cleaner and
also beneficial to your health.

Before you install and use this water purifier, please be sure to read the user manual, this enables

qualified   and   standardised   installation   as   well   as   reasonable   use   and   maintenance   to   maximise   the
effectiveness of your water purifier.

If you experience difficulties during installation or usage, please contact your local distributor to carry

out repairs or maintenance for you.

-1-

Summary of Contents for NEW LINE A

Page 1: ...ter that can be consumed directly so the water you drink is cleaner and also beneficial to your health Before you install and use this water purifier please be sure to read the user manual this enable...

Page 2: ...Installation Preparations 12 2 Instructions for Proper Installation 13 3 Installation Notes 13 Testing Methods 16 Usage Methods 17 Maintenance and Upkeep 17 1 Filter Replacement Time 17 2 Filter Repla...

Page 3: ...not put heavy objects on the water purifier If heavy objects are placed on the water purifier it may result in damage to the water purifier s dust cover or internal components which could lead to leak...

Page 4: ...waste water ratio device are clogged it may lead to high TDS effluent the RO membrane may get blocked or the water purifier may not work Water purifier inlet water temperature should not exceed 38 If...

Page 5: ...ed disassembly or modification of the machine could lead to machine malfunctions and leakage accidents For example the system s pump type D cannot be installed on the system model A B or C In this cas...

Page 6: ...ction 1 Blown up profile of the water purifier The system could be in 2 versions based on normal bracket or stable bracket Normal Bracket Stable Bracket with Pressure meter Diagram 1 2 Electrical diag...

Page 7: ...s per day Model NAME NEW LINE A NEW LINE A NEW LINE B NEW LINE B NEW LINE C NEW LINE C NEW LINE D NEW LINE D Voltage AC 220 240 V 50HZ 24V 1 8A AC 220 240 V 50HZ 24V 2 2A AC 220 240 V 50HZ 36V 1 5A AC...

Page 8: ...ype II Type II Hardness level max mg ekv lit 8 8 8 8 8 8 8 8 MAX pure water flow per day Lit 40 40 40 40 80 80 120 140 120 140 Notes Due to product improvements the above parameters may change but the...

Page 9: ...e RO membrane Flow Restrictor Waste Water Ratio Device controls waste water flow Low Voltage Switch To prevent pump idling When the inlet water pressure is less than 0 03 MPa or when the inlet water s...

Page 10: ...ately after long work period of time The limit time of flashing could be between 0 5 1 5 min the light is on when the drinking goose neck faucet closed The light is on when the machine purify the wate...

Page 11: ...close machine will flush membrane 30 seconds The pump and inlet solenoid and flush solenoid are all off The buzzer will beep 10 times Full Function 1 If the high pressure switch is open and the machi...

Page 12: ...same time the machine is producing water This design solves the contamination problem such as odours bacteria etc caused by long time pure water storage in tank It supplies the real pure and fresh wa...

Page 13: ...box wrap one end of the ball valve external threads with the appropriate Teflon tape See Diagram 5 if you have silica gel spread a little on and then screw the ball valve into the corresponding hole...

Page 14: ...Take the first RO membrane from its packaging put the end of the membrane with the O ring into the reverse osmosis membrane shell See Diagram 9 and push it in finally screw the membrane shell cover ba...

Page 15: ...brane components the membrane manufacturer does not assume responsibility for returned components due to damage during installation Damage to the membrane shell and reverse osmosis membrane element ca...

Page 16: ...ter will start to drain through the discharge outlet 2 Wait for the water purifier to operate stably about 5 10 seconds check each connection to make sure it is secure see if there is any leakage from...

Page 17: ...ty and utilisation rate and the average indicators there will be more obvious differences between the filter s actual use time and the estimated cycle such as premature filter clogging premature failu...

Page 18: ...ce the filter inside the filter cartridge use the wrench to tighten the filter cover For replacement of membrane elements please see RO Membrane Installation Page 8 3 Notes RO membrane water productio...

Page 19: ...easure the output voltage replace The high pressure pump is working properly but no water is being produced High pressure pump has lost pressure Measure the water pump pressure replace Inlet water sol...

Page 20: ...s the final explanation rights if this manual is unclear has mistakes or if there were printing problems which caused problems Packing List Main machine including 2 units of RO membranes 1 unit Water...

Reviews: