8
to create one’s own fall arrest system where each safety function can interfere with another safety function.
Therefore, it is important to read the
recommendations on using each component in the system before use.
VERIFICATION:
The recommended service life of the equipment is 10 years, but it may be increased or reduced according to use and/or the results of the annual
inspections.
The equipment should be inspected if there is any doubt, or following a fall, and at least annually, by the manufacturer or a competent person* and in
strict compliance with the manufacturer’s periodic inspection procedures (and in particular the inspection guides ref. GI XX-XXXXXX-XX) to check
its strength and therefore the user’s safety. The product data sheet should be completed (by writing) after each verification; date of inspection and date of
next inspection must be indicated on the data sheet, it is also recommended to put date of next inspection on the product.
*: refer to the definition of a competent person on our website under: Info/Technical Advice
SERVICING AND STORAGE;
(Comply strictly with these instructions)
During transport, keep the product in its packaging, well away from any cutting surface; clean it with water, wipe it with a rag and hang it up in a well-
ventilated location, to let it dry naturally and away from a naked flame or heat source; follow the same procedure for components that have become damp
during use. The system must be stored in its packaging in a dry, well aired place protected from extremes of temperature.