![Kratki LEO Series Installation And Operating Instructions Manual Download Page 32](http://html1.mh-extra.com/html/kratki/leo-series/leo-series_installation-and-operating-instructions-manual_2002584032.webp)
32
Attention!!!
All activities related to connecting the device to the gas installation should be
carried out with the power off. The insert may be installed only by a qualified
fitter / service technician with appropriate qualifications.
Attention!!!
It is strictly forbidden to use open fire during the gas cartridge installation
process. Failure to follow the instructions can result in fire or explosions,
causing serious damage, damage to health, and even death..
Technical specification of the gas control system used in the LEO series:
FULFILLED DIRECTIVES 2009/142/EC
and DIN EN 298, DIN EN 126, DIN EN
13611
FUEL
Gaseous fuels of the first, second and third families
according to PN-EN 437: 2003 + A1: 2009 and
product standard PN-EN 613: 2002 + A1: 2004
PRESSURE DROP /
CAPACITY
2,5 mbar for 1,2 m
3
/h
ADJUSTMENT RANGE
Class C according to EN 88
REDUCER ADJUSTMENT
5 to 40 mbar (0,5 to 4 kPa)
MOUNTING POSITION
he module must not be mounted with the chopper
block facing down. The position of the controller can
be adjusted from 0 ° to 90 ° relative to its basic
position.
MAXIMUM PRESSURE
INPUT GAS
50 mbar (5 kPa)
CONNECTING THE MAIN
GAS INLET
1/2'' to 3/8'' reducing nipple
CONTROL BURNER
CONNECTION
M10x1 for 6 mm pipe
DEPARTURE OF CHIEF
gas inlet and outlet
On side or on a bottom of the valve
MAXIMUM TORQUE
TIGHTENING
3/8 "inlet and outlet connection: 35 Nm
Control burner connection: 15 Nm
THERMOCOUPER /
INTERRUPTOR BLOCK
M10x1, M9x1, M8x1
IGNITION
Piezo ignition
PERMISSIBLE
OPERATING
TEMPERATURE
Controller (Valve): 0 °C to 80 °C
Receiver without batteries: 80 °C
Receiver with batteries: 55 °C
Remote controller
: 60 °C
Ignition cable: 150 °C