It is allowed to lead the horizontal terminal below 2.5 m above ground level, but not
less than 0.5 m if there is no playground or other recreational places within 8 m. The
distance between the cable outlets should not be less than 3 m, and the distance of
these outlets from the nearest edge of the opening windows / doors (
G
) and screening
projections (
F
) not less than 0.5 m (
C
and
G
). A distance of at least 6 m should be kept
between the flue gas outlet and smoke outlet and the nearest edge of the adult tree
crown. Below is how the vertical terminal is positioned relative to the ridge (
I
) and the
obstacle interfering with air flow (
J
).
I
Distance from the ridge
* for a roof covered with straw ≥ 0.8 m
J
Distance from an obstacle