![Kratki LEO/100 Manual Instruction Download Page 55](http://html1.mh-extra.com/html/kratki/leo-100/leo-100_manual-instruction_2002586055.webp)
• It is forbidden to make any changes in the design of
the device.
• Fireplaces should not be cleaned with caustic agents.
• When replacing individual components, use only original spare parts available from the
manufacturer.
No
Scope
Steps
1
General
inspection
Perform lighting a fire in the fireplace.
Check the operation of all safety systems.
Check that the main burner flame burns steadily.
Check that the main burner flame burns evenly.
Check the batteries in the receiver and the remote control do not need to be replaced.
Check the operation of all modes in the control unit.
2
Glass
inspection
Make sure that the glass does not have any cracks Make sure the glass fits tight to
the body of the fireplace.Check the wear of the glass sealing cords. If necessary,
replace the sealing cords.
Check the degree of dirtiness of the glass. If necessary, clean the glass.
3
Switch box
inspection
Check the tightness of gas connections.
Make sure the switch box has adequate ventilation.
Check that the cables connecting the controller to the receiver are not damaged.
Make sure gas control system components are not exposed to high temperatures.
Make sure that the switch box is not exposed to moisture. Check that the connecting
cords have no signs of corrosion.
4
Combustion
chamber
inspection
Make sure the control burner is not obscured by decorative elements.
Check if the thermocouple is within the control flame. Check whether the combustion
chamber requires cleaning.
Make sure all air inlets to the combustion chamber are clear. If necessary, clear the
openings.
Check the tightness of the body of the fireplace.
Check the combustion chamber with respect to any signs of corrosion. If necessary,
remove corrosion and cover losses with a new coating of paint. Check that the main
burner ignites smoothly.
5
Control of the
chimney system
If possible, check the tightness of the chimney system. Check the coaxial combustion
air system patency.
6
Control device
inspection
Check that the receiver antenna is not damaged. Make sure that the main valve knob
and the manual mode dial work correctly.
Check if there is no insulation damaged in the circuits. Make sure the AC power cord
is not damaged. Make sure that the control system components are not exposed to
overheating.
7
Trim inspection
Make sure the gas insert trim has no cracks.
Make sure that combustible elements are at a safe distance from the fireplace trim.
Summary of Contents for LEO/100