![Krantz VIRUSPROTECT Operating Manual Download Page 9](http://html1.mh-extra.com/html/krantz/virusprotect/virusprotect_operating-manual_2002492009.webp)
Operating Manual Krantz
VIRUS
PROTECT
Page
9
Subject to technical changes.
4.5
Personnel Qualifications
Persons who use this device must:
be aware of the dangers that arise when working with electrically-operated air purifiers,
have read and understood the operating instructions, especially the section on safety.
4.6
Residual Risks
,
Warnings about Electrical Voltage
Work on electrical components may only be carried out by an authorized specialist.
Before performing any work on the device, remove the power plug from the power socket!
Unplug the power cord from the power socket by gripping the plug.
4.7
What to Do in an Emergency
1. Turn off the device.
2. In an emergency, disconnect the device from the power supply: Pull the connection cable out of
the power socket by gripping the power plug.
3. Do not reconnect a defective device to the power supply.
4. Contact the manufacturer or have the device checked and repaired by an authorized specialist.
5. Device Description and Sites of Operation
The Krantz VIRUS
PROTECT
filter device is used to filter room air in recirculation mode.
It is preferably used in heavily frequented public areas and reliably reduces the number of virus particles,
microorganisms, particulate matter, and aerosols.
The filtration efficiency of the HEPA filter element in use is 99.995% in the MPPS.
1)
This means that almost all virus particles, bacteria, fungal spores, allergens, and germs are retained in the
HEPA filter.
Thanks to the patented inactivating lining of the pre-filter and HEPA filter elements, together with the lined filter
housing, these retained virus particles and microorganisms are inactivated. In other words, almost (more than
99.95%
2)
) all viruses and microorganisms are killed.
This prevents the uncontrollable proliferation of any microorganisms, viruses, or otherwise potentially harmful
material.
No additional energy sources, such as UV-C light or thermal heat sources, are required to inactivate these
viruses and microorganisms. The Krantz VIRUS
PROTECT
works in a purely passive manner.
By not using heating systems or UV-C light, there are
no
hazardous substances when operating the Krantz
VIRUS
PROTECT
. The device works 100% ozone free.
The brushed stainless steel sheeting is corrosion-resistant and possesses an antibacterial effect from the
ions on its chrome-nickel surface.
For typical locations of the device, see 4.3 Intended Use.
1)
Most Penetrating Particle Size
2)
Source: OFI (Österreichisches Forschungs- und Prüfinstitut)