KRAMER: SIMPLE CREATIVE TECHNOLOGY
Technical Specifications
24
8
Technical Specifications
The
VS-88HD
technical specifications are shown in
Table 6
:
Table 6: VS-88HD Technical Specifications
1
INPUTS:
8 SMPTE-259M, 344M, 292M and 372M (dual link) serial video,
75ΩonBNCconnectors
OUTPUTS:
8 equalized and reclocked SMPTE-259M, 344M, 292M and 372M
(dual link)
outputs75ΩonBNCconnectors
MAX. OUTPUT LEVEL:
800mVpp /
75Ω
DATA RATE:
1.485Gbps
EQUALIZATION:
Automatic equalization for losses on 75
coaxial cable
CONTROLS:
Front-panel, RS-232, RS-485, ETHERNET, remote infrared
POWER SOURCE:
Universal, 100-240V AC, 50/60Hz 24VA
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
-40° to +70°C (-40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
DIMENSIONS:
19" x 7" x 1U W, D, H, rack mountable
WEIGHT:
2.6kg (5.7lbs) approx.
INCLUDED ACCESSORIES:
Power cord,
rack“ears”andIR remote control transmitter
OPTIONS:
External remote IR receiver cable
9
Communication Parameters
The following table lists the communication parameters for Protocol 2000
and Protocol 3000.
Table 7: Communication Parameters
EDID
EDID data is passed between Input 1 and Output 1
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81
Example (Output 1 to Input 1):
#AV 1>1<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel:
Press LOCK and OUT 3 at the same
time
Front Panel:
Press LOCK and OUT 2 at the same
time
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Power cycle the unit while holding in the Factory Reset button,
located on the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
1 Specifications are subject to change without notice