KRAMER: SIMPLE CREATIVE TECHNOLOGY
Controlling via RS-232 and RS-485
12
6 Controlling via RS-232 and RS-485
You can cascade up to 16
VS-4x4YCxl
units with control from a PC or serial
controller.
To cascade up to 16 individual
VS-4x4YCxl
units, via RS-232 and RS-485,
do the following:
1. Connect the s-Video sources and acceptors, as well as the appropriate
stereo audio sources and acceptors, as section 5.1 describes.
2. Connect the RS-232 port on the first
VS-4x4YCxl
unit to the PC using
the Null-modem adapter provided with the machine (recommended), as
section 5.2 describes.
3. Connect the RS-485 terminal block port on the first
VS-4x4YCxl
unit to
the RS-485 port on the second
VS-4x4YCxl
unit and so on, connecting
all the RS-485 ports.
4. Set the dipswitches, as section 5.5 describes. In particular:
Set the first
VS-4x4YCxl
unit as MACHINE # 1 and the following
15
VS-4x4YCxl
units as MACHINE # 2 to MACHINE # 16,
according to Table 4.
Set DIP 8 ON on the first and last
VS-4x4YCxl
units (terminating
the RS-485 line at 120 ). Set DIP 8 OFF on the other
VS-4x4YCxl
units
Set DIP 5, DIP 6 and DIP 7 OFF on all
VS-4x4YCxl
units