background image

Kramer Protocol 2000 

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

16 

7  Kramer Protocol 2000 

The 

VS-311H

 is compatible with Kramer’s Protocol 2000

1

Table 6: Protocol Definitions 

 (version 0.46) 

(below). This RS-232/RS-485 communication protocol uses four bytes of 
information as defined below. For RS-232, a null-modem connection between 
the machine and controller is used. The default data rate is 9600 baud, with 
no parity, 8 data bits and 1 stop bit. 

MSB 

 

 

 

 

 

 

LSB 

 

DESTI- 
NATION 

INSTRUCTION 

N5 

N4 

N3 

N2 

N1 

N0 

1st byte 

 

INPUT 

I5 

I4 

I3 

I2 

I1 

I0 

2nd byte 

 

OUTPUT 

O6 

O5 

O4 

O3 

O2 

O1 

O0 

3rd byte 

 

 

 

MACHINE NUMBER 

OVR 

M4 

M3 

M2 

M1 

M0 

4th byte 
 
1

st

 BYTE: 

Bit 7 – Defined as 0  

D – “DESTINATION”: 

0 - for sending information to the switchers (from the PC); 

1 - for sending to the PC (from the switcher)  
N5

N0 – “INSTRUCTION” 

The function that is to be performed by the switcher(s) is defined by the INSTRUCTION (6 bits)  Similarly, if a function is 
performed via the machine’s keyboard, then these bits are set with the INSTRUCTION NO , which was performed  The 
instruction codes are defined according to the table below (INSTRUCTION NO  is the value to be set for N5

N0)  

 
2

nd

 BYTE: 

 

Bit 7 – Defined as 1  

 

 

I6

I0 – “INPUT”  

When switching (ie  instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched  
Similarly, if switching is done via the machine’s front-panel, then these bits are set with the INPUT NUMBER which was 
switched  For other operations, these bits are defined according to the table  
 
3

rd

 BYTE: 

 

Bit 7 – Defined as 1  

                     

O6

O0 – “OUTPUT”  

When switching (ie  instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched  
Similarly, if switching is done via the machine’s front-panel, then these bits are set with the OUTPUT NUMBER which was 
switched  For other operations, these bits are defined according to the table  
 
4

th

 BYTE:  

Bit 7 – Defined as 1   

 

 

Bit 5 – Don’t care   

 

 

OVR – Machine number override  

 

      

M4

M0 – MACHINE NUMBER  

Used to address machines in a system via their machine numbers

                                                       

 

1  You can download our user-friendly “Software for Calculating Hex Codes for Protocol 2000” from our Web site: 

http://www kramerelectronics com

 

 When several machines are controlled from a single serial 

port, they are usually configured together with each machine having an individual machine number  If the OVR bit is set, then 
all machine numbers will accept (implement) the command, and the addressed machine will reply  

Summary of Contents for VS-311H

Page 1: ...Kramer Electronics Ltd USER MANUAL Model VS 311H Automatic HDMI Audio Switcher...

Page 2: ...4 5 4 3 Control Configuration via the Ethernet Port 14 6 Technical Specifications 15 7 Kramer Protocol 2000 16 Figures Figure 1 VS 311H Automatic HDMI Audio Switcher 6 Figure 2 Connecting the VS 311H...

Page 3: ...software2 Windows based Ethernet Configuration Manager and Virtual Serial Port Manager Kramer RC IR3 Infrared Remote Control Transmitter including the required battery and a separate user manual3 Pow...

Page 4: ...Getting Started KRAMER SIMPLE CREATIVE TECHNOLOGY 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Page 5: ...hes to the highest priority input according to the input priority setup2 When selecting an INPUT SELECT button via the manual or auto mode that button illuminates Pressing an illuminated button desele...

Page 6: ...ation between the video source such as a DVD player and the digital television enabling new functionality such as automatic configuration and one button play HDMI has the capacity to support Existing...

Page 7: ...fferent network location Gateway A network position serving as an entry to ano her network On the Internet a node or stopping point can be either a gateway node or a host end point node IP Address A 3...

Page 8: ...AMER SIMPLE CREATIVE TECHNOLOGY 6 4 Your VS 311H Automatic HDMI Audio Switcher Figure 1 illustrates the front and rear panels of the VS 311H Table 2 defines the front and rear panels of the VS 311H Fi...

Page 9: ...tors Connect to he digital audio S PDIF inputs from 1 to 3 9 RS 232 DB 9F Port Connect to the PC or the Remote Controller 10 PRIORITY SETUP DIP switches DIP switches for setup of the machine DIPs 1 2...

Page 10: ...eptor for example an AV receiver 5 1 6 If required connect a PC and or controller to the RS 232 port see section 5 3 and or the ETHERNET port see section 5 4 7 If required connect7 the contact closure...

Page 11: ...Connecting the VS 311H Automatic HDMI Audio Switcher 9 Figure 2 Connecting the VS 311H Automatic HDMI Audio Switcher...

Page 12: ...y setup Set the inputs priority see Table 4 4 AUTO OFF manual mode switch between channels manually ON automatic mode inputs switch automatically to the output according to the priority setup Inputs 1...

Page 13: ...contact closure remote control pins operate in a similar way to the input buttons For example you may override1 the presently routed input by using the remote control contact closure To do so2 connect...

Page 14: ...re 5 Crossed Cable RS 232 Connection Hardware flow control is not required for this unit In the rare case where a controller requires hardware flow control short pin 1 to 7 and 8 and pin 4 to 6 on the...

Page 15: ...commended for identifying the VS 311H with the factory configured default IP address After connecting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your de...

Page 16: ...necting the ETHERNET Port via a Network Hub Straight Through Cable You can connect the Ethernet port of the VS 311H to the Ethernet port on a network hub or network router via a straight through cable...

Page 17: ...an RCA connector 1 unbalanced stereo audio 4dBm on a 3 5mm mini jack with 1 balanced stereo audio on a 5 pin detachable terminal block COMPLIANCE WITH HDMI STANDARD Supports HDMI HDCP compliant DATA...

Page 18: ...below INSTRUCTION NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be sw...

Page 19: ...the instruction is performed due to a keystroke operation on the front panel then these codes are sent For example if the HEX code 01 85 88 83 was sent from the PC then the switcher machine 3 will swi...

Page 20: ...ning orotheractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims...

Page 21: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: