Step 6: Set operation parameters via OSD menu 

 

 

Menu Item 

Function 

Enter the OSD menu via the MENU button on the 
front panel or the IR remote control transmitter. 
Select a menu item and set parameters as 
required. 

 

Inputs 

Sets the parameters for each input connector such 
as input type, native resolution, color depth, HDCP 
mode, audio input level and so on 

 

Layout 

Sets the display mode, transition settings (transition 
speed, mode, effects, direction, and take) and 
overlay settings (single window and PIP types), as 
well as output resolution and other output settings 

If you cannot see any video output, verify that the 
display, TV, or projector is in good working order 
and is connected to the  

VP-778

. Verify that the 

VP-778 

is selected as the 

source. If you still cannot see any video output, 
press and hold the RESET TO XGA/720P button 
for 3 seconds to reset the output to XGA or 720p 
resolution. 

Channel 1 / Channel 2 

Sets the parameters for the Channel 1 / Channel 2 
output including the source, aspect ratio, color 
settings, de-interlacing, noise reduction, projection, 
power save settings, test patterns, audio settings 
and so on 

Misc 

Displays the information, OSD settings, USR 
keypad settings, FW upgrade and factory reset 

 

Step 7: Operate via the front panel buttons and via the: 

IR remote controller: 

RS-232 and Ethernet: 

 

 

RS-232 

 

Protocol 3000 

 

Baud Rate:  

115,200  

Stop Bits:  

1  

Data Bits:  

8  

Parity:  

None  

Example (decrease the volume on input 5):  

#Y 0,116,-,5<CR> 

TCP/IP Parameters  

 

IP Address:  

192.168.1.39  

UDP Port #:  

50000  

Subnet mask:  

255.255.000.000  

Maximum UDP Connections:  

Unlimited 

Default gateway:  

192.168.0.1 

Maximum TCP Connections:  

Unlimited 

TCP Port #:  

5000  

 

 

Full Factory Reset

 

 

OSD  

Factory Reset through the Misc menu item  

Protocol 3000  

Including ETH: use “Factory” command or #Y 0,561,1<CR>   

 

Excluding ETH: use “Factory” command or #Y 0,561,1<CR>   

Front panel 
buttons 

Including ETH: power up the device with the “RESET TO XGA/720P” key 
pressed 

 

Step 8: Pass serial data via the device: 

The 

VP-778 

lets you route serial data through its various ports in the following ways: 

 

 

Serial matrix

 – up to eight sets of unidirectional connections can be configured for passing serial data from a selected source 

to a selected destination.  
Select the source/destination ports: port tunneling, the DATA RS-232 port, HDBT IN1, HDBT IN2 HDBT OUT1 or HDBT 
OUT2. 

 

USR buttons

 – a programmable serial command passes to a selected destination with a press of a USR button.  

Select the destination ports: port tunneling, the DATA RS-232 port, HDBT IN1, HDBT IN2 HDBT OUT1, HDBT OUT2 or all 

 
 