Kramer VP-727A Protocol (Ver. 3.21)
25
INSTRUCTION
1
st
Byte
2
nd
Byte
3
rd
Byte
4
th
Byte
COMMENT
READ BASS
19
B1
80
81
READ TREBLE
19
B2
80
81
READ BALANCE
19
B3
80
81
READ PROGRAM INPUT 1
DELAY
19
C1
80
81
READ PROGRAM INPUT 2
DELAY
19
C2
80
81
READ PROGRAM INPUT 3
DELAY
19
C3
80
81
READ PROGRAM INPUT 4
DELAY
19
C4
80
81
READ PROGRAM INPUT 5
DELAY
19
C5
80
81
READ PROGRAM INPUT 6
DELAY
19
C6
80
81
READ PROGRAM INPUT 7
DELAY
19
C7
80
81
READ PROGRAM INPUT 8
DELAY
19
C8
80
81
See NOTE 3
AFV
08
80
80
81
BREAKAWAY
08
80
81
81
See NOTE 1
READ AFV / BREAKAWAY
STATUS
0B
80
80
81
See NOTE 3
FADE ON
20
80
81
81
See NOTE 1
FADE OFF
20
80
80
81
See NOTE 1
READ FADE STATUS
21
80
80
81
See NOTE 3
TAKE
3A
80
81
81
See NOTE 1
TAKE INSTRUCTION
COMPLETE
3A
81
81
81
See NOTE 4
CANCEL TAKE
3A
80
80
81
IDENTIFY MACHINE
3D
81
80
81
See NOTE 5
IDENTIFY FIRMWARE VERS. 3D
83
80
81
See NOTE 6
STORE SETUP
13
80+SETUP
80
81
ERASE STORED SETUP
13
80+SETUP
81
81
See NOTE 1
RECALL SETUP
14
80+SETUP
80
81
See NOTE 1
IS SETUP DEFINED?
0D
80+SETUP
80
81
See NOTE 3
LOCK
1E
81
80
81
Lock panel
See NOTE 1
UNLOCK
1E
80
80
81
Unlock panel
See NOTE 1
READ LOCK STATUS
1F
80
80
81
See NOTE 3