Step 3:  Mount VP-558 

To rack mount the machine, attach both 
rack ears (by removing the screws from 
each side of the machine and replacing 
those screws through the rack ears) or 
place the machine on a table.  

 

 

  Ensure that the environment (e.g., maximum ambient 

temperature & air flow) is compatible for the device. 

  Avoid uneven mechanical loading. 

  Appropriate consideration of equipment nameplate ratings 

should be used for avoiding overloading of the circuits. 

  Reliable earthing of rack-mounted equipment should be 

maintained. 

Step 4:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

VP-558

 

Balanced stereo 
audio connection: 

 

Unbalanced stereo 
audio output 
connection: 

 

Balanced Stereo 
Audio Input 
Connection 

 

Unbalanced Stereo 
Audio Input 
Connection 

 

 

 

 

 

Wiring the RJ-45 Connectors 

 

To achieve specified extension 
distances, use the recommended 
Kramer cables available at 

www.kramerav.com/product/VP-
558

. 

Using third-party cables may cause 
damage! 

 

This section defines the TP pinout, 
using a straight pin-to-pin cable with 
RJ-45 connectors.

 

EIA /TIA 568B 

 

PIN 

Wire Color 

Orange / White 

Orange 

Green / White 

 

For HDBT cables, it is recommended 

that the cable ground shielding be 

connected/soldered to the connector 

shield. 

Blue 

Blue / White 

Green 

Brown / White 

Brown 

 

 

Step 5:  Connect power 

Connect the power cord to 

VP-558

 and plug it into the mains electricity.  

Safety Instructions (See www.kramerav.com for updated safety information) 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

  Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. 

  To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit

 

  Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75. 

Peut être installé dans des salles de matériel de traitement de l’information conformément à l’article 645 du National Electrical Code et à la NFPA 75.

 

 

 

  

  

  

  