background image

Using the VM-24HC 2 Input 1:4 HDMI Distributor 

 

2.  Connect the HDMI OUTPUT connectors

1

 to up to 4 HDMI acceptors 

using Kramer HDMI copper cables. In this example

2

, connect: 

 

OUTPUT 1 to display device 1 (for example, an LCD TV) 

 

OUTPUT 2 to display device 2 (for example, an LCD TV) 

 

OUTPUT 3 to display device 3 (for example, an LCD TV) 

 

OUTPUT 4 to display device 4 (for example, a plasma display) 

3.  If required, connect a PC and/or controller to the RS-232 port (see 

Section  5.2

). 

4.  Connect the power adapter to the device and to the mains electricity 

(not shown i

Figure 2

)

5.  If required, acquire the EDID (see 

Section  5.4

). 

5.2  Selecting an Active Input 

To select an active input: 

 

Press the INPUT SELECTOR button to toggle between inputs 1 and 2 

5.3  Connecting a PC/Controller via RS-232  

You can connect a PC or serial controller to the 

VM-24HC 

using the 

RS-232 connection. Note that a null-modem adapter/connection is not 

required. 

To connect to the VM-24HC via RS-232: 

 

Connect the RS-232 9-pin D-sub rear panel port on the 

VM-24HC

 

unit via a 9-wire straight cable (only pin 2 to pin 2, pin 3 to pin 3, and 

pin 5 to pin 5 need to be connected) to the RS-232 9-pin D-sub port on 

your PC/controller 

5.4  Acquiring the EDID  

Initially

3

 the 

VM-24HC

 operates with the factory default EDID

4

 stored in 

the non-volatile memory. The source reads the EDID from the device 

when the device is plugged in or powered on.  
 
 
 

                                                       

 

1 As required. Up to four outputs can be connected. Not all outputs need to be connected 
2 Only connections to the first and last acceptors are shown in 

Figure 2

 

3 This is usually done only once when the unit is being set up in an installation. Once acquired, the EDID is saved in non-
volatile memory and further acquisition is not necessary 
4 The VM-2DH reads the EDID, which is stored in the non-volatile memory 

Summary of Contents for VM-24HC

Page 1: ...Kramer Electronics Ltd USER MANUAL Model VM 24HC 2 Input 1 4 HDMI Distributor...

Page 2: ...t 7 5 3 Connecting a PC Controller via RS 232 7 5 4 Acquiring the EDID 7 6 Technical Specifications 9 7 Default Communication Parameters 9 8 Default EDID 10 9 Communication Protocol 12 Figures Figure...

Page 3: ...following items VM 24HC 2 Input 1 4 HDMI Distributor Power adapter 5V DC output RC IR3 Infrared Remote Control This user manual3 2 Getting Started We recommend that you Unpack the equipment carefully...

Page 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation...

Page 5: ...ressed all digital3 audio video interface widely supported in the entertainment and home cinema industry It delivers the highest high definition image and sound quality In particular HDMI4 Provides a...

Page 6: ...y to describe its capabilities to an HDMI source The EDID enables the VM 24HC to know what kind of monitor is connected to the output The EDID includes the manufacturer s name the product type the tim...

Page 7: ...CT Press to select the EDID source single output Auto Mix or default 6 OUTPUT LEDs 1 to 4 Lights green when an output is connected and active LED flashes to indicate the source of the EDID acquired se...

Page 8: ...4 5 1 Connecting the VM 24HC 2 Input 1 4 HDMI Distributor Figure 2 Connecting theVM 24HC 2 Input 1 4 HDMI Distributor To connect1 the VM 24HC as illustrated in the example in Figure 2 1 Connect2 the...

Page 9: ...ial controller to the VM 24HC using the RS 232 connection Note that a null modem adapter connection is not required To connect to the VM 24HC via RS 232 Connect the RS 232 9 pin D sub rear panel port...

Page 10: ...tton briefly once causes the relevant LEDs to indicate which EDID is stored at the input as follows OUTPUT 1 LED flashes the EDID from OUTPUT 1 was the last acquired OUTPUT 2 LED flashes the EDID from...

Page 11: ...C 1 1A OPERATING TEMPERATURE 0 to 55 C 32 to 131 F STORAGE TEMPERATURE 45 to 72 C 49 to 162 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 21 5cm x 16 3cm x 4 4cm 8 5 x 6 4 x 1 7 W D H WEIGHT 0 6kg...

Page 12: ...iming 1280x720p at 60Hz 16 10 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750 hsync vsync Standard timings supported 720 x 400p at 70Hz IBM VGA 640 x 480p at 60Hz IBM VGA 640 x 480p at 75...

Page 13: ...ter No Rear LFE No Report information Date generated 08 Dec 11 Software revision 2 60 0 972 Data source File Operating system 5 1 2600 2 Service Pack 3 Raw data 00 FF FF FF FF FF FF 00 2E 4D 23 00 01...

Page 14: ...I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s front panel then these bit...

Page 15: ...a request to identify the switcher s in the system If the OUTPUT is set as 0 and the INPUT is set as 1 2 5 or 7 the machine will send its name The reply is the decimal value of the INPUT and OUTPUT Fo...

Page 16: ...roduct modification orfailure to follow instructions supplied withtheproduct iii Repair orattemptedrepairby anyone not authorized by Kramer iv Any shipment of theproduct claims must bepresentedtothe c...

Page 17: ...latest information on our products and a list of Kramer distributors where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect th...

Reviews: