background image

 

 

TP-590R

 

 

Feature 

Function 

14 

ACTIVE HOST LED 

Lights orange when the device is enabled as an active USB host (see 

Step 4:

 

Connect inputs and outputs

)

15 

IN LED 

Lights blue when an active HDMI input signal device is detected on HDBT IN. 

16 

OUT LED 

Lights blue when an output device is connected to the HDMI OUT. 

17 

LINK LED 

Lights green when the HDBT active link connection is established. 

18 

ON LED 

Lights green when the device receives power. 

19 

HDBT IN

 

RJ-45

 

Connector 

Connect to the HDBT OUT RJ-45 connector on the HDBT transmitter. 

20 

HDMI OUT

 

Connector

 

Connect to the HDMI acceptor. 

21 

HOST USB 2.0 Connector

 

Connect to the USB host (for example, a room PC) to communicate with the USB 
peripheral devices (for example, a room camera) connected to USB device ports on 
either the transmitter or the receiver. 

22 

USB 2.0 Charging Connectors (3)

 

Connect to the USB local peripheral devices (for example, USB camera, a 
soundbar, speakers and so on). 

23 

RS-232 3-pin Terminal Block

 

Connect to a serial device to be controlled. 

24 

IR 3.5mm Mini Jack Connector

 

Connect to an external IR emitter to control a local IR-controlled device from the 
transmitter side (for example, 

TP-590T

). 

Connect to an IR sensor to control a remote IR-controlled device connected to the 
transmitter side (for example, 

TP-590T

). 

25 

SETUP 4-way DIP-switch 

Sets the device behavior (see 

Step 4:

 

Connect inputs and outputs

)

26 

5V DC Power Connector 

Connect to the power supply. 

 

The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. 

Step 3:  Mount TP-590T and TP-590R 

Install 

TP-590T

 and 

TP-590R

 using one of the following methods: 

  Attach the rubber feet and place the unit on a flat surface. 

  Fasten a bracket (included) on each side of the unit and attach it to a flat surface 

(see 

www.kramerav.com/downloads/TP-590T

 and/o

www.kramerav.com/downloads/TP-590R

)

 

  Mount the unit in a rack using the recommended rack adapter  

(see 

www.kramerav.com/product/TP-590T

 and/or 

www.kramerav.com/product/TP-590R

)

 

  Ensure that the environment (e.g., maximum ambient temperature & 

air flow) is compatible for the device. 

  Avoid uneven mechanical loading. 

  Appropriate consideration of equipment nameplate ratings should be 

used for avoiding overloading of the circuits. 

  Reliable earthing of rack-mounted equipment should be maintained. 

  Maximum mounting height for the device is 2 meters. 

  

Reviews: