background image

 

TP-121xl/TP-122xl - Getting Started 

 

2.3 

About the Power 

Connect™ Feature 

The Power Connect™ feature here means that only one unit in a system, the 

transmitter or receiver, needs to be connected to a power source when the 

devices are within 60m (197

ft) of each other. The Power Connect™ feature 

applies as long as the cable can carry power and the distance does not exceed 

60m on standard TP cable. (Heavier gauge cable may be used to extend the 

Power Connect

™ range.)  

2.4 

Shielded Twisted Pair/Unshielded Twisted Pair  

We recommend that you use Shielded Twisted Pair (STP) cable, and stress that 

the compliance to electromagnetic interference was tested using STP cable. 

There are different levels of STP cable available, and we advise you to use the 

best quality STP cable that you can afford. Our non-skew-free cable, Kramer 

BC-STP

 is intended for analog signals where skewing is not an issue. 

In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-free 

cable, Kramer 

BC-XTP

, may be advantageous, and UTP cable might also be 

preferable for long range applications. In any event when using UTP cable, it is 

advisable to ensure that the cable is installed far away from electric cables, motors 

and so on, which are prone to create electrical interference. 

2.5 

Recycling Kramer Products 

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC 

aims to reduce the amount of WEEE sent for disposal to landfill or incineration by 

requiring it to be collected and recycled. To comply with the WEEE Directive, 

Kramer Electronics has made arrangements with the European Advanced 

Recycling Network (EARN) and will cover any costs of treatment, recycling and 

recovery of waste Kramer Electronics branded equipment on arrival at the EARN 

facility. For details of Kramer’s recycling arrangements in your particular country 

go to our recycling pages at 

http://www.kramerelectronics.com/support/recycling/

 

 

Summary of Contents for TP-121xl

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODELS TP 121xl UXGA Audio Line Transmitter TP 122xl UXGA Audio Line Receiver P N 2900 300261 Rev 4...

Page 2: ......

Page 3: ...dio Line Receiver 7 5 Connecting the TP 121xl Transmitter and TP 122xl Receiver 8 6 Operating the TP 121xl and TP 122xl 10 6 1 Capturing the EDID 10 6 2 Adjusting the Level and Equalization on the TP...

Page 4: ...clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Spe...

Page 5: ...ity due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighbo...

Page 6: ...ls where skewing is not an issue In cases where there is skewing our Unshielded Twisted Pair UTP skew free cable Kramer BC XTP may be advantageous and UTP cable might also be preferable for long range...

Page 7: ...and reception system The TP 121xl encodes computer graphics video and unbalanced stereo audio into a TP signal The TP 122xl decodes the TP signal into computer graphics video and digital unbalanced s...

Page 8: ...TP 122xl accepts the encoded signal over STP from the TP 121xl and outputs computer graphics video unbalanced stereo audio and digital audio 4 1 Defining the TP 121xl UXGA Audio Line Transmitter Figu...

Page 9: ...eature Function 4 UXGA IN 15 pin HD Connector F Connect to a computer graphics source see Section 5 5 LINE OUT RJ 45 Connector Connect to the Line In RJ 45 connector on the TP 122xl see Section 2 2 6...

Page 10: ...ization level 4 ON LED Lights green when the device is powered on Figure 4 defines the rear panel of the TP 122xl Figure 4 TP 122xl UXGA Audio Line Receiver Rear Panel Feature Function 5 UXGA OUT 15 p...

Page 11: ...After connecting your TP 121xl TP 122xl connect the power to the transmitter and receiver and then switch on the power to the other devices Figure 5 Connecting the TP 121xl Transmitter and TP 122xl R...

Page 12: ...th speakers The Audio Out S PDIF RCA connector to the digital audio acceptor for example a DAT recorder 3 Using STP cabling connect the TP 121xl Line Out RJ 45 connector to the TP 122xl Line In RJ 45...

Page 13: ...olid If the EDID is not successfully captured the Status LED flashes quickly for a few seconds then lights solid when the default EDID is loaded 6 2 Adjusting the Level and Equalization on the TP 122x...

Page 14: ...tor shield Figure 6 defines the TP pinout using a straight pin to pin cable with RJ 45 connectors EIA TIA 568B Figure 6 TP Pinout Wiring PIN Wire Color 1 Orange White 2 Orange 3 Green White 4 Blue 5 B...

Page 15: ...Video 1 1V Audio 2 2V AUDIO BANDWIDTH Audio 20Hz 20kHz 3dB S N RATIO Audio 84dB unweighted COUPLING AC TND N Audio 0 02 unweighted TOTAL GAIN Analog analog 0dB Analog SPDIF 12dBFS POWER CONSUMPTION 12...

Page 16: ......

Page 17: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300261 Rev 4 SAFETY...