The 

SG-6006

 is a broadcast quality, multi-standard SPG (Sync Pulse Generator) 

with black burst, color bar, and audio tone outputs. It has eight composite video 
and four SDI outputs on BNC connectors. The analog video outputs—and the four 
SDI outputs—can be configured as either a black burst or a color bar signal.  

In particular, the 

SG-6006

 

Has audio outputs available in AES 75

 (AES-3id) and AES-EBU digital 

formats, as well as in unbalanced and balanced analog audio formats 

 

Has balanced audio and AES/EBU outputs on XLR connectors, AES 75

Ω 

(AES-3id), SDI and composite video outputs on BNC connectors, and 
unbalanced audio outputs on RCA connectors. All outputs are available 
simultaneously 

 

Offers a choice of nine color bars (for video outputs), and you can set the 
timing parameters, SCH and phase 

 

Features adjustments for the frequency and amplitude  

 

Features various options for SDI audio embedding 

 

Can be genlocked to an external composite video source via its looping input 
with selectable termination  

The 

SG-6006

 is housed in a 19” 1U rack mountable enclosure, and is fed from a 

100-240 VAC universal switching power supply. 

The 

SG-6006

 can be operated via the front panel buttons with an LCD and a user-

friendly menu, and remotely operated via the RS-232 interface

1

3.1 

Recommendations for Best Performance 

To achieve the best performance: 

 

Connect only good quality connection cables, thus avoiding interference, 
deterioration in signal quality due to poor matching, and elevated noise levels 
(often associated with low quality cables) 

 

Avoid interference from neighboring electrical appliances that may adversely 
influence signal quality and position your 

SG-6006

 away from moisture, 

excessive sunlight and dust 

Defining the SG-6006 Genlock Multistandard SPG/SDI/Audio 
Generator 

Figure 1

 and 

Table 1

 define the front and rear panels of the 

SG-6006

                                                       

 

1 The Communication Protocol is available on request from Kramer support  

Summary of Contents for SG-6006

Page 1: ...Kramer Electronics Ltd USER MANUAL Model SG 6006 Genlock Multistandard SPG SDI AUDIO Generator...

Page 2: ...he SG 6006 8 7 1 Operating the SG 6006 8 7 2 Locking the Front Panel 10 7 3 Remotely Operating the SG 6006 via RS 232 10 8 Technical Specifications 11 Figures Figure 1 SG 6006 Front and Rear Panels 4...

Page 3: ...following items SG 6006 Genlock Multistandard SPG SDI Audio Generator Power cord rack ears and Null modem adapter Windows based Kramer control software3 This user manual4 2 Getting Started We recommen...

Page 4: ...Getting Started KRAMER SIMPLE CREATIVE TECHNOLOGY 2...

Page 5: ...res various options for SDI audio embedding Can be genlocked to an external composite video source via its looping input with selectable termination The SG 6006 is housed in a 19 1U rack mountable enc...

Page 6: ...Defining the SG 6006 Genlock Multistandard SPG SDI Audio Generator KRAMER SIMPLE CREATIVE TECHNOLOGY 4 Figure 1 SG 6006 Front and Rear Panels...

Page 7: ...n additional machine to loop the genlocking source 13 TERM Button When looping release the TERM button When not looping terminate the line by pressing the button 14 ANALOG VIDEO OUTPUT BNC Connectors...

Page 8: ...Installing the SG 6006 in a Rack KRAMER SIMPLE CREATIVE TECHNOLOGY 6 5 Installing the SG 6006 in a Rack This section describes what to do before installing in a rack and how to rack mount...

Page 9: ...onnect the VIDEO OUTPUT BNC connectors to up to eight composite video acceptors2 OUTPUT 1 to a non linear editor for example OUTPUT 6 to a studio camera OUTPUT 8 to an input on the Kramer VS 808xl 8x8...

Page 10: ...it in the line and release the TERM button for looping3 5 If required connect a PC and or controller to the RS 232 port see Section 7 6 Connect the power connector to the mains electricity 1 7 Using t...

Page 11: ...SILENT ANALOG RIGHT LEVEL 19dBU 25dBu to 12dBu 6dBu 19dBu 25dBu ANALOG RIGHT CHANNEL SILENT ACTIVE SILENT DIGITAL 1 L LEVEL5 31dBFS to 0dBFS 31dBFS DIGITAL 1 L CHANNEL5 SILENT ACTIVE SILENT DIGITAL 2...

Page 12: ...006 Press the LOCK button for more than three seconds until the LOCK button lights The front panel is locked Pressing a button will have no effect other than causing the LOCK button to flash2 To unloc...

Page 13: ...on BNC connectors 0 8Vpp 75 1 stereo balanced analog audio on 2 XLR connectors 12dBu max 1 unbalanced stereo analog audio on 2 RCA connectors 6dBu max 2 AES EBU digital audio on XLR connectors 0dBFS...

Page 14: ...t misuse abuse neglect fire water lightning or otheractsofnature ii Product modification orfailure to follow instructions supplied withtheproduct iii Repairorattemptedrepairby anyonenot authorizedbyKr...

Page 15: ...REV 2 For the latest information on our products and a list of Kramer distributors visit www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and...

Reviews: