TAKING CARE OF YOUR MACHINE 

Do not locate  your machine in an environment where it is susceptible to dust or moisture. Both of these may 

damage the electronics, and cause erratic operation or failure. Do not locate  your machine where temperature 

and  humidity  may  be  excessive.  Doing  so  may  also  damage  the  electronics,  and  cause  erratic  operation  or 

failure of your machine. Do not clean your machine with abrasives or strong cleaners. Doing so may remove or 

damage the finish, or may allow moisture to build up. Take care not to allow dust or particles to build up inside 

unused or open connectors. 

 

TROUBLESHOOTING 

NOTES

 

1.  Please note that if the output signal is disturbed or interrupted 

by very strong external electromagnetic interference, it should 

return  and  stabilize  when  such  interference  ends.  If  not, 

disconnect  power  from  the  machine  and  reconnect  again  to 

reset the machine.   

2.  If  the  following  recommended  actions  still  do  not  result  in 

satisfactory operation, please consult your KRAMER Dealer. 

Power and Indicators 

Problem 

Remedy 

No Power 

1. 

Confirm that the rocker switch is in the “ON” position, and that the switch is 

illuminated. 

2. 

Confirm that power connections are secured at the machine and at the 

receptacle. Make sure the mains receptacle is active. If still there is no power, 

remove power cord from AC outlet and then, using a flat head screwdriver, 

remove the fuse holder located directly below the power connector on your 

machine.  

3. 

Confirm that the fuse is good by looking for the wire connected between the 

ends of the fuse. If the wire is broken, replace the fuse with another, with the 

same rating. 

 

Video Signal 

Problem 

Remedy 

No video at the output 

device, regardless of 

input selected. 
 

1.  Confirm that all devices are powered on and connected properly.  

2.  Confirm that any other device in the signal path have the proper input and/or 

output selected. 

3.  Confirm that the maximum cable length is not exceeded.  

 

Summary of Contents for SG-6005

Page 1: ...KRAMER ELECTRONICS Ltd USER MANUAL Kramer Genlock Multistandard Black Burst Bar Generator Model SG 6005 IMPORTANT Before proceeding please read paragraph entitled Unpacking and Contents...

Page 2: ...SG 6005 11 10 1 Structure Of Protocol 12 10 2 Description of Instructions 13 10 3 Relationship Between Switched Data and Display 16 11 INSTALLATION 16 11 1 Rack Mounting 16 11 2 Connecting to Video an...

Page 3: ...s controllers and computer related products This manual includes configuration operation and option information for the SG 6005 VIDEO SYNC AND RELATED PROBLEMS All video signals arriving at a monitor...

Page 4: ...e not identical as the Green signal has a larger amplitude due to the sync it carries and the sync signals must be stripped off in order to recover the normal green sync level A subset of this format...

Page 5: ...of other negative effects The main cause of the above mentioned problems is improper analog sync levels In the logic level sync world this shouldn t happen At least in theory However other problems le...

Page 6: ...re commands to ignore those incorrect signals and those controls should be activated Alternatively a sync shaver machine should be used one for each of the Red and Blue channels This device shaves off...

Page 7: ...Zero Ohm connection resistance is the objective Sockets and connectors also must match the required impedance 75ohm in video Cheap low quality connectors tend to rust thus causing breaks in the signal...

Page 8: ...lanced audio signals using XLR connectors Using a simple front panel switch it can be configured as a 1 10 for mono signals or as a 1 5 for stereo signals In either mode its purpose is to accept a sin...

Page 9: ...2 3 PAL OR NTSC Selects the video standard of the machine The illuminated switch indicates the selected standard To change the video standard press the non illuminated switch The machine takes about a...

Page 10: ...ne will still delay according to the previously selected settings The selection allows display and control of this function not the enabling and disabling of it 8 V SYNC OUT Selects deselects the cont...

Page 11: ...y now indicates the B Y value of the matte which may be changed using the and buttons 11 Pressing the BAR button 10 yet again will causes the decimal point to flash in the third digit of the 7 segment...

Page 12: ...or not to insert a pedestal 7 5 IRE setup when generating NTSC The switch is ON if the pedestal is to be used 23 POWER SOCKET Mains inlet socket The fuse is located within the socket RESETTING THE SG...

Page 13: ...e taken not to set a switcher with this machine number STRUCTURE OF PROTOCOL MSB LSB INSTRUCTION 0 TO PC I5 I4 I3 I2 I1 I0 7 6 5 4 3 2 1 0 1st byte DATA 1 D6 D5 D4 D3 D2 D1 D0 7 6 5 4 3 2 1 0 2nd byte...

Page 14: ...ding set EXTENDED DATA as 0 When receiving LSB of EXTENDED DATA status of front panel switch The PC sends this instruction to the machine The machine replies by setting the EXTENDED DATA according to...

Page 15: ...s instruction was sent Note further that the addressed front panel switch does not need to be pressed in order to change its value via RS 232 If the or button is pressed on the machine resulting in a...

Page 16: ...e machine replies with DATA as the version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex a...

Page 17: ...splayed data PAL no Genlock switch data 103 X 1 40625 degr Displayed data PAL Genlock switch data 179 X 1 40625 degr Displayed data NTSC no Genlock switch data 36 X 1 40625 degr Displayed data NTSC Ge...

Page 18: ...port to the provided Null Modem adapter Connect the Null modem adapter to the RS 232 port of the SG 6005 using a flat cable with the appropriate sockets TURNING ON THE MACHINE NOTES 1 The machine sho...

Page 19: ...18 KRAMER ELECTRONICS LTD Figure 3 RS 232 Null Modem Connection...

Page 20: ...connect again to reset the machine 2 If the following recommended actions still do not result in satisfactory operation please consult your KRAMER Dealer Power and Indicators Problem Remedy No Power 1...

Page 21: ...covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorize...

Page 22: ...tries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may...

Page 23: ...m P N 2900 004005 REV 2 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www k...

Reviews: