RC-76M
/
RC-712M - Installing the RC-76M/RC-712M
11
4.2.1.2
Connecting RS-485 Devices
You can control up to one AV device by connecting it to the
RC-76M
/
RC-712M
via
its RS-485 connection.
To connect a device to the
RC-76M
/
RC-712M
via RS-485:
Connect the A (+) pin of the device to the
A
pin on the RS-485 terminal block
of the
RC-76M
/
RC-712M
Connect the B (-) pin of the device to the
B
pin on the RS-485 terminal block of
the
RC-76M
/
RC-712M
Connect the G pin of the device to the
GND
pin on the RS-485 terminal block
of the
RC-76M
/
RC-712MRC-76M
If your device is the first or last device on the line, slide the RS-485 termination
switch up, otherwise make sure it is set to down (see
4.3
Connecting the Ethernet Port
The Ethernet connection of the
RC-76M
/
RC-712M
lets you perform all control
functions of the
RC-76M
/
RC-712M
over the Internet using a PC running the
Kramer Site-CTRL control program to control AV devices.
To connect the
RC-76M
/
RC-712M
to a network:
1. Connect the Ethernet port of the
RC-76M
/
RC-712M
to the Ethernet port on a
network hub or network router, via a straight cable with RJ-45 connectors.
2. At the other end, connect the Internet to a PC running
Site-CTRL
.
3. After connecting the Ethernet port, you have to install and configure it. For
detailed instructions on how to install and configure your Ethernet port, see
the
K-Config Software Guide.