Step 4:  Connect the input and output 

Always switch OFF the power on each device before connecting it to your 

PT-12

. For best results, we recommend that you 

always use Kramer high-performance cables to connect AV equipment to 

PT-12

DIP-switch setup 

A switch that is down is on; a switch that is up is off. By default, all the switches are up (off). 

 

Note that you can set color space as pass-through (default) or RGB color space via 
P3K commands. 

 

Feature 

Description 

EDID Lock 

Off (up)

—Lock the current EDID so that changes on the output do not result in 

changes to the EDID.  

On (down)

—EDID is passed-through and acquired automatically. 

Deep Color 

Off (up)

—Limit color depth to 8 bits per color. 

On (down)

—Pass-thru color depth parameters. 

Audio Pass-through 

Off (up)

—Audio transmission is limited to 2-channel LPCM only. 

On (down)

—Audio transmission is passed-through. 

 

 

 

Audio pass-thru setup takes-effect only when DIP-switch 1 is Off (EDID locked), 
otherwise ignored.  

HDCP Operation 

Off (up)

— HDCP is disabled: The input port declares that HDCP is not supported even 

when HDCP is detected on the output port. 

On (down)

—HDCP is enabled: If the sink supports HDCP, the input port declares 

HDCP support and actively handles HDCP on the output and input port. If the sink does 
not support HDCP, the input port declares that HDCP is unsupported. 

CEC Control 

Off (up)

—CEC auto on/off control is enabled. 

On (down)

—CEC auto on/off is disabled. 

6, 7 Display Auto Shutdown 

Enable/disable auto shutdown delay (before 5V output cut-off) of the connected display 
(via output 5V-off setup) when no active input signal is detected. 

 

 

DIP 6 

DIP 7 

Delay before Auto Shutdown (before 5V output cut-off) 

 

 

Off 

Off 

Auto Shutdown is disabled 

 

 

On 

Off 

5s 

 

 

Off  

On 

1m 

 

 

On 

On 

15m 

CPU FW Upgrade 

Off (up)

—Normal operation mode. 

On (down)

—CPU firmware upgrade mode. 

 

 

 

When set to ON the device is inactive. 

 

Step 5:  Connect the power 

Connect the 5V DC power adapter to 

PT-12

 and plug it into the mains electricity. 

Safety Instructions  

 

Caution: 

There are no operator serviceable parts inside the unit.

 

Warning: 

Use only the Kramer Electronics power adapter that is provided with the unit. 

Warning: 

Disconnect the power and unplug the unit from the wall before installing. 