background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Communication Protocol (Ver 0.1) 

 

10 

DESCRIPTION OF INSTRUCTIONS 

INSTRUCTION 0 – RESET 

DATA=0: initialize the machine. 
When the machine is initialized, it will send the RESET code (DATA = 0). If the machine receives this code, it will reset to 
its “power-up” state. 
DATA=1: configure the machine to its factory default state. 
When the machine receives this code, all programmable parameters will be reset to their factory-default values. 
EXTENDED DATA - set as 0. 
 

INSTRUCTION 3 – STORE MACHINE SETTINGS 

DATA = setup# (1 to 10) where present values of machine settings are saved. 
EXTENDED DATA - set as 0. 
- When the machine receives this instruction, its present settings (video parameters) are saved in non-volatile memory. The 
machine replies by sending the same 4 bytes (except for the Destination Bit) back to the PC. 
- When the user saves the machine settings using the front-panel buttons, then this instruction is sent to the PC. 
 

INSTRUCTION 4 – RECALL MACHINE SETTINGS 

DATA = setup# (1 to 10) of machine settings which are to recalled. 
EXTENDED DATA - set as 0. 
- When the machine receives this instruction, it recalls the settings which were previously saved in the setup#. The machine 
replies by sending the same 4 bytes (except for the Destination Bit) back to the PC. 
- When the user recalls a setup using the front-panel buttons, then this instruction is sent to the PC. 
 

INSTRUCTION 5dec – SET VIDEO PARAMETER 

DATA = Video parameter #, defined as follows: 
1 = Brightness 
2 = Contrast 
3 = Hue 
4 = Sharpness 
5 = Colour saturation 
6 = R-Y saturation 
7 = B-Y saturation 
EXTENDED DATA - value for selected video parameter . 
- When the machine receives this instruction, then, if valid, the selected video parameter is set and the machine replies by 
sending the same 4 bytes (except for the Destination Bit) back to the PC. 
- When the user changes video parameters using the front-panel buttons, then this instruction is sent to the PC. 
Note that the video parameter values range from 0 (minimum) up to 255dec (maximum), and do not necessarily correspond 
with the number displayed on the panel of the 7408. If a value outside the legal range of a particular parameter is sent, the 
error code will be returned. 
 

INSTRUCTION 6 – REQUEST VIDEO PARAMETER 

For sending to machine, DATA = VIDEO parameter #, defined as in INSTRUCTION 5; EXTENDED DATA=0; 
When replying DATA = VIDEO parameter #, defined as in INSTRUCTION 5; EXTENDED DATA- value for selected 
VIDEO parameter. 
 

INSTRUCTION 7 – READ VIDEO ENCODER DATA 

For sending to machine, DATA = VIDEO ENCODER sub-address which is to be read. 
When replying:- DATA = VIDEO ENCODER sub-address; EXTENDED DATA = requested data. 
The PC sends this instruction to the machine. The machine replies by sending back the data assigned to this sub-address. 
 

INSTRUCTION 8 – WRITE VIDEO ENCODER DATA 

DATA = VIDEO ENCODER sub-address; EXTENDED DATA = data to be written to this sub-address. 
The PC sends data directly to the encoder. The machine implements this new value, and replies by sending the same 4 bytes 
(except for the Destination Bit) back to the PC. 
CAUTION – this function was designated for development and testing purposes. Improper use of this function may cause 
erratic behaviour of the machine. 
 

INSTRUCTION 10dec – WRITE EEPROM DATA 

DATA = EEPROM sub-address; EXTENDED DATA = data to be written to this sub-address. 
The PC sends data directly to the EEPROM. The EEPROM stores this new value, and replies by sending the same data back 
to the PC. 

Summary of Contents for DigiTOOLS 7408

Page 1: ...Kramer Electronics Ltd Preliminary USER MANUAL Model 7408 SDI to Analog Converter...

Page 2: ...Communication Protocol Ver 0 1 9 Figures Figure 1 7408 SDI to Analog Converter 4 Figure 2 Connecting a 7408 SDI to Analog Converter 6 Figure 3 Crossed Cable RS 232 Connection 6 Figure 4 Straight Cabl...

Page 3: ...ms 7408 SDI to Analog Converter Power supply Null modem adapter Windows based Kramer control software This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save...

Page 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Page 5: ...ws PC software provided for ProcAmp control via RS 232 for adjusting parameters such as contrast hue saturation and sharpness NTSC encoding with or without a 7 5IRE setup A perforated cover to prevent...

Page 6: ...video or composite video and or s Video acceptors according to DIP switch selection see Table 3 3 U Y BNC connector 4 Y CV 5 SDI OUT BNC Connector Connects to the reclocked and equalized SDI acceptor...

Page 7: ...uch as an SDI monitor 2 Connect the following An s video acceptor such as an s video monitor to the C Y output BNC connectors and or A composite video acceptor such as a composite video monitor to the...

Page 8: ...ample a PC A crossed cable or null modem is required as shown in method A and B respectively If a shielded cable is used connect the shield to pin 5 Method A Figure 3 Connect the RS 232 9 pin D sub po...

Page 9: ...ect only these 3 pins or all 9 pins Figure 4 Straight Cable RS 232 Connection with a Null Modem Adapter 5 3 Setting the DIP Switches Configure the 7408 unit by setting the DIP switches as Table 2 defi...

Page 10: ...technical specifications Table 4 Technical Specifications1 of the 7408 SDI to Analog Converter INPUT 1 SDI SMPTE 259M ITU R BT 601 on a BNC connector OUTPUTS 1 reclocked SDI SMPTE 259M ITU R BT 601 on...

Page 11: ...7 and the EXTENDED DATA E7 are in the fourth byte Terminology TO PC is the DESTINATION BIT I4 I0 is the INSTRUCTION D7 D0 is the DATA E7 E0 is the EXTENDED DATA The destination bit TO PC is 0 when sen...

Page 12: ...e machine receives this instruction then if valid the selected video parameter is set and the machine replies by sending the same 4 bytes except for the Destination Bit back to the PC When the user ch...

Page 13: ...fixed standard the 7408 will reply by sending the code for the fixed standard INSTRUCTION 16dec ERROR If the machine receives an invalid instruction it replies by sending this error code INSTRUCTION 3...

Page 14: ...g orotheractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims mus...

Page 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: