KRAMER: SIMPLE CREATIVE TECHNOLOGY
CAT 5 Serial Control/Command
6
If x = a stored preset, the new preset configuration will be saved in
preset memory
location x.
Parameters:
x = Preset (0 - 8)
a = Output 1 input selection (0 = OFF)
b = Output 2 input selection (0 = OFF)
:
h = Output 8 input selection (0 = OFF)
5.7 Recall Commands
The following Recall Command formats shall be used:
Rx<CR>
: Recall preset (x) and copy to current working preset.
Device replies with:
P0=a,b,c,d,e,f,g,h<CR><LF>
Parameters:
a = Output 1 input selection (0 = OFF)
b = Output 2 input selection (0 = OFF)
:
h = Output 8 input selection (0 = OFF)
5.8 Status Commands
The following Recall Command formats shall be used:
S=<CR> :
Report master device status.
Device replies with:
Px=a,b,c,d,e,f,g,h<CR><LF>
P1=a,b,c,d,e,f,g,h<CR><LF>
P2=a,b,c,d,e,f,g,h<CR><LF>
P3=a,b,c,d,e,f,g,h<CR><LF>
P4=a,b,c,d,e,f,g,h<CR><LF>
P5=a,b,c,d,e,f,g,h<CR><LF>
P6=a,b,c,d,e,f,g,h<CR><LF>
P7=a,b,c,d,e,f,g,h<CR><LF>
P8=a,b,c,d,e,f,g,h<CR><LF>
Parameters:
x = Current (working) preset If x = 1 – 8 then a stored preset is
loaded. If any output configuration is changed after loading a stored
preset, then x = 0.
a = Output 1 input selection (0 = OFF)