CAT 5 Serial Control/Command
5
5.5 Output Commands
The following Output Command formats shall be used:
Ox=<CR>
: Report an output (x) channel configuration.
Device replies with:
Ox=y<CR><LF>
Parameters:
x = Output channel (1 - 8)
y = Input channel assigned to selected output channel (0 = OFF)
Ox=y<CR>
: Configure an output (x) channel.
Device replies with:
Ox=y<CR><LF>
Parameters:
x = Output channel (1 - 8)
y = Input channel assigned to selected output channel (0 = OFF)
5.6 Preset Commands
The following Preset Command formats shall be used:
Px=<CR> : Report a preset (x) configuration.
Device replies with:
Px=a,b,c,d,e,f,g,h<CR><LF>
Parameters:
x = Preset (0 - 8) – If x = 0, the current (working) configuration is
reported.
a = Output 1 input selection (0 = OFF)
b = Output 2 input selection (0 = OFF)
:
h = Output 8 input selection (0 = OFF)
Px<CR>
: Saves current (working) configuration as a preset (x) configuration.
Device replies with:
Preset x Stored! <CR><LF>
Parameters:
x = Preset (1 - 8)
Px=a,b,c,d,e,f,g,h<CR>
: Configures a preset.
Device replies with:
Preset x Stored! <CR><LF>
If x = 0 or if x = a recalled preset, the current working preset is reported
as:
P0=a,b,c,d,e,f,g,h<CR><LF>