908 - 908 Commands in Protocol 3000
21
9
908 Commands in Protocol 3000
This RS-232/RS-485 communication protocol lets you control the machine from
any standard terminal software (for example, Windows® HyperTerminal
Application) and uses a data rate of 115200 baud, with no parity, 8 data bits, and 1
stop bit.
This section describes all commands sent to the
908
. For an explanation of the
syntax and use of Protocol 3000, see Section
9.10
.
9.1
Operating Commands
Following are the specific commands that the room controller (RC device) sends to
the
908
to operate the external devices.
9.2
Help Commands
Command
Syntax
Response
Protocol handshaking
#CR
~OKCRLF
9.3
Device Initiated Messages
Command
Syntax
Start message
Kramer Electronics LTD. , Device Model Version
Software Version
Switcher actions:
Audio channel has switched (breakaway mode)
AUD IN>OUT
9.4
Result and Error Codes
Syntax
Command ran successfully, no error.
COMMAND PARAMETERS OK
Protocol Errors:
Syntax error
ERR001
Command not available for this device
ERR002
Parameter is out of range
ERR003
Unauthorized access (command run without the
matching login).
ERR004