Charger (in the case of Art. No.: 45.140.57 it
is not included in delivery)
•
Original Operating Instructions
•
Safety information
3. Intended use
The cordless pole-mounted pruner is designed
for cutting o
ff
branches from trees. It is not suita-
ble for extensive sawing work, cutting down trees
or sawing any materials other than wood.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Pole-mounted pruner
Cutter bar length: ................................... 200 mm
Max. cutting length: ................................ 180 mm
Chain pitch: .................................... 3/8“, 33 teeth
Chain thickness: .........................(0.047“) 1.2 mm
Sprocket wheel: ............................... 5 teeth, 3/8“
Cutting speed
at rated rpm: .............................................4.5 m/s
Oil tank capacity: ..................................... 35 cm³
Net weight without accessories: .................3.2 kg
Saw chain: ...............................Oregon/91P033X
Cutter bar: .........................Oregon 080NDEA041
Protection class: ................................................III
Battery (lithium-ion)
Voltage ............................................. 18 V
Capacity ................................................... 3.0 Ah
18 V Kraftixx battery charger
Mains voltage ..........200-250 V~, 50-60 Hz, 72 W
Output voltage/current .... 20 V
/ 3000 mA
Danger!
Noise and vibration
Sound and vibration values were measured in
accordance with ISO 3744.
Sound pressure level L
pA
.................... 77.8 dB(A)
Uncertainty K
pA
.............................................3 dB
Measured sound power level L
WA
...... 92.1 dB(A)
Uncertainty K
WA
............................................3 dB
Guaranteed sound power level L
WA
...... 102 dB(A)
Wear ear-mu
ff
s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) were determined in accordance with ISO
5349-1 and ISO 5349-2.
Handle (front)
Vibration emission value a
h
= 2.050 m/s
2
Uncertainty K = 1.5 m/s
2
Handle (rear)
Vibration emission value a
h
= 1.672 m/s
2
Uncertainty K = 1.5 m/s
2
The speci
fi
ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the speci
fi
ed value
in exceptional circumstances.
The speci
fi
ed vibration value can be used to
compare the equipment with other electric power
tools.
The speci
fi
ed vibration value can be used for initi-
al assessment of a harmful e
ff
ect.
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
•
Wear protective gloves.