9.4.2 Inspection: Discharge flow
The discharge flow is measured via the flow rate volume counters.
The values are displayed by the built-in controller in the electrical control system.
–
If there is no discharge flow, check the individual components of the product.
–
Comply with the product-specific data sheets/operating instructions.
9.4.3 Inspection: Operating pressure
The operating pressure is indicated by the pressure gauges.
–
If there is no operating pressure, check the individual components of the product.
–
Comply with the product-specific data sheets/operating instructions.
9.4.4 Inspection: Media temperature
The media temperature is measured through the temperature sensor.
The values are displayed by the built-in controller in the electrical control system.
–
If the media temperature is too high or too low, check the product components.
–
Comply with the product-specific data sheets/operating instructions.
9.4.5 Inspection: Condition of operating fluid
Pay attention to colour (dark colouring), odour and milky turbidity.
–
Replace operating fluid if necessary.
9.4.6 Audiometric monitoring: Unusual noise
In this case, attention must be paid to increased noise or uneven operation (pump unit).
–
In case of unusual noises, check the individual components of the product, line at-
tachments and the operating media for foam formation.
–
Comply with the product-specific data sheets/operating instructions.
9.4.7 Cleaning
Remove dust deposits and dirt with a damp, clean cloth.
9.4.8 Visual inspection: Leakages
Care must be taken here to ensure that there is no leakage from the connections.
–
In the event of leaks in the connections, the glands must be tightened and, if neces-
sary, the seals replaced.
9.4.9 Visual inspection: Measuring unit status
In this case, attention must be paid to the measuring unit of the product.
Summary of Contents for VC PULSE Series
Page 1: ...VC PULSE English 03 04 01 2021 D 0046020002 Operating Instructions Translation ...
Page 18: ...4 Technical data Kracht GmbH 18 46 88046020002 VC 0 2 VC 0 4 VC 1 ...
Page 19: ...Kracht GmbH Technical data 4 88046020002 19 46 VC 3 VC 5 VC 12 VC 16 ...
Page 20: ...4 Technical data Kracht GmbH 20 46 88046020002 4 4 2 Plain bearings VC 0 025 VC 0 1 ...
Page 21: ...Kracht GmbH Technical data 4 88046020002 21 46 VC 0 2 VC 0 4 VC 1 ...
Page 26: ...4 Technical data Kracht GmbH 26 46 88046020002 4 9 Dimensions ...