10 | Repairs
Kracht GmbH
46 / 46
88046020002
10.3 Detecting and eliminating failures
TIPP
If the unit does not function properly, the electrical components should be checked first. The
measuring instrument must remain in operation for this.
Fault
Potential causes
Possible measures
LED display
Both LED displays flash -
however, false values are
displayed in the overrid-
ing controller
Connection between the device
plug and the overriding control-
ler is loose/defective
Check the connection and re-
place the cable or plug if neces-
sary
An LED display does not
illuminate
Wire break
Repairs by manufacturer
Soldering point defective
Sensor defective
No LED display illumin-
ates
Power failure
Check the supply cable
Check the fuses
Measuring unit is blocked
Put the device out of operation
immediately!
Repairs by manufacturer
Seal failure
/
Leakage
O-Ring in the device is defective
Repairs by manufacturer
Check material compatibility
O-ring between housing and
connection plate defective
Replace O-ring.
Defective values in the overriding controller
Wear
Repairs by manufacturer
In case of unidentified faults, request help from the manufacturer or return the unit to the
manufacturer for inspection.
Summary of Contents for VC PULSE Series
Page 1: ...VC PULSE English 03 04 01 2021 D 0046020002 Operating Instructions Translation ...
Page 18: ...4 Technical data Kracht GmbH 18 46 88046020002 VC 0 2 VC 0 4 VC 1 ...
Page 19: ...Kracht GmbH Technical data 4 88046020002 19 46 VC 3 VC 5 VC 12 VC 16 ...
Page 20: ...4 Technical data Kracht GmbH 20 46 88046020002 4 4 2 Plain bearings VC 0 025 VC 0 1 ...
Page 21: ...Kracht GmbH Technical data 4 88046020002 21 46 VC 0 2 VC 0 4 VC 1 ...
Page 26: ...4 Technical data Kracht GmbH 26 46 88046020002 4 9 Dimensions ...