EN
Voltage / Continuity / Single Pole Mode
TP5000HY
• When batteries are not
fitted or are exhausted, the
tester still work when
measuring> 45VAC and/or
>35VDC.
• Timing Rating (tr):
30 seconds, Recovery
Time (rt): 240seconds,
when measuring >300V,
recovery time is necessary.
• L/R LED may light up when
measuring AC voltage.
• Due to the high internal
resistance, capacitive and
inductive Voltage (ghost
voltage) may be indicated.
Warning
- Clockwise Phase Sequence
L1-L2-L3(Right)
- Counterclockwise Phase
Sequence L1-L3-L2(Left)
Phase Rotation Test works only on 3 phase 4 wire system.
The result is unreliable on other systems.
It is necessary to check the result by test with reverse sequence.
LED indicates measured
voltage is high than ELV limit
(50VAC and/or 120VDC).
V
AC
DC
1000
690
400
L
R
RX
12
AC
V
230
120
50
24
12 -
-
+
AC
12
+
+DC
12
-DC
+
V
AC
DC
1000
690
400
L
R
RX
12
V
230
120
50
24
+
-
DC
Voltage Measurement
Phase Rotation Test