Kozy-World GSN2821 Owner'S Operation & Installation Manual Download Page 7

                                    7

CLEARANCES TO
COMBUSTIBLES
(Vent-Free  Operation  Only)
Carefully  follow  the  instructions  below.
This  stove  is  a  freestanding  unit
designed  to  set  directly  on  the  floor.

IMPORTANT

:

 

 You  must  maintain

minimum  wall  and  ceiling  clearances
during  installation. The  minimum
clearances  are  shown  in  Figure  4.
Measure from  outermost  point  of  stove
top.

Minimum Wall and Ceiling
Clearances
(see Figure 4)
A.   Clearances   from   outermost   point

of stove top to any combustible side
wall should not be less  than 12
inches.

B.   Clearances  from outermost point of

stove top to any combustible back
wall should not  be less than 6
i n c h e s   ( l n c l u d e s   c o r n e r
installations).

C.   Clearances  from  the  stove top to

the ceiling should not be less than
48 inches.

CONNECTING  TO  GAS
SUPPLY

          WARNING:  A  qualified  service
person  must  connect  heater  to  gas
supply. Follow  all  local  codes.

         CAUTION:    Never      connect
heater  directly  to  the  propane/LP
supply.  This  heater  requires an
external  regulator (not  supplied).
lnstall  the  external  regulator  between
the  heater  and  propane/LP  supply.

No external regulator needed for natu-
ral gas  models.

INSTALLATION   ITEMS
NEEDED
Before  installing  heater, make  sure
you  have  the  items  listed  below.

piping (check  local  codes)

l

    sealant (resistant to propane/LP gas)

l

   equipment  shutoff  valve*

l

   test  gauge  connection*

l

   sediment  trap

l

   see  joint

l

   pipe  wrench

A  CSA  design-certified  equipment
shutoff   valve   with 1/8

 NPT  tap  is

an acceptable  alternative  to  test
gauge  connection. Purchase  the
o p t i o n a l     C S A     d e s i g n - c e r t i f i e d
equipment  shutoff  valve from your
dealer. See  Accessories.

Figure  5 -Gas  Regulator  Location
and  Gas  Line  Access  Into  Stove
Cabinet

Figure  6 -External  Regulator  With
            Vent  Pointing  Down

Figure  7 -Gas  Connection

FOR  LP  models
The  installer  must  supply  an  external
regulator.  The  external  regulator  will
reduce  incoming  gas  pressure. You
must  reduce  incoming  gas  pressure
to  between  11 to 14

 inches  of  water.

If you do not reduce incoming gas
pressure, heater regulator damage
could  occur. lnstall external regulator
with  the  vent  pointing  down  as  shown
in  Figure  6.  Pointing  the  vent  down
protects  it  from  freezing  rain  or  sleet.

*   Purchase  the  optional  CSA  design-certified  equipment  shutoff  valve  from
    your  dealer. See  

Accessories

, page  13.

*   Minimum  inlet  pressure  for  purpose  of  input  adjustment.

Propane/LP
Supply Tank

FOR NG models:
(4” W.C.-10.5”W.C.)
No External Regulator Needed

Summary of Contents for GSN2821

Page 1: ......

Page 2: ...mbustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with o...

Page 3: ...69 This heater is designed for vent free operation State and local codes in some areas prohibit the use of vent free heaters UNPACKING 1 Remove top inner pack 2 Tilt carton so that stove is upright 3...

Page 4: ...You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms wi...

Page 5: ...room unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be...

Page 6: ...the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls CAUTION This heater creates warm air currents These currents move heat to wall surfac...

Page 7: ...l gas models INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below l piping check local codes l sealant resistant to propane LP gas l equipment shutoff valve l t...

Page 8: ......

Page 9: ......

Page 10: ...l o w e r a s s e m b l y temporarily on top panel 12 Install control knob onto output shaft of operation control housing see figure 16 Place operation control housing just inside control compartment...

Page 11: ......

Page 12: ......

Page 13: ...er Maximum 14 Minimum 11 NG Manifold Pressure 3 0 W C Inlet Gas Pressure In of water Maximum 10 5 Minimum 5 Dimensions Inches H W D Stove 27 1 2 27 7 8 17 1 2 Carton 21 3 4 30 1 16 31 1 2 Weight pound...

Page 14: ...gas company B Clean ODS pilot see Cleaning and Maintenance or replace ODS pilot assembly 6 Replace thermocouple 7 Replace control valve POSSIBLECAUSE 1 Ignitor electrode positioned wrong 2 Ignitor ele...

Page 15: ...flame holes blocked 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance or replace burner orifi...

Page 16: ...ions page 8 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 8 1 This is common with most heaters If noise is...

Page 17: ......

Page 18: ...1 2 5 4 5 T I S e v l a V l o r t n o C t a t s o m r e h T 1 8 0 0 0 2 5 4 5 T I S e v l a V l o r t n o C t a t s o m r e h T 1 9 0 0 0 1 3 3 B S y l b m e s s A e b u T t e l t u O 1 0 1 2 0 3 8 0...

Page 19: ...1 9 ILLUSTRATED PARTS BREAKDOWN GSN2821 GSP2822...

Page 20: ...b e r i F 1 8 0 1 0 4 1 0 L S r o t c e l f e D t a e H 1 9 0 1 0 5 6 0 L S w e r c S g n i p p a t f l e S 4 0 1 1 0 8 0 0 L S r o o l F x o b e r i F 1 1 1 1 0 4 0 0 L S l e n a P t n o r F r e w o...

Page 21: ...e drawings to put log sets in place to the gas pedestal stove indoor vent free NOTICE THE POSITION OF THE LOGS SHOULD AVOID FLAME 1 Take out the paper liner See DRAWING 1 2 Take away the screen from t...

Page 22: ...2 2...

Page 23: ...of log B See Figure 3 3 Place the upper part of log D on the flat roof at the left side of log A Insert the pinhole on the lower part of log D into the pin on log C See Figure 4 4 Insert the pinhole o...

Reviews: