2.   Open  gas supply tank valve.
3.   Make sure control knob of heater is

in the OFF  position.

4.   Check all  joints from  equipment

shutoff  valve  to  co ntrol  valve
(LP  GAS  see  Figure  9.1  NATURAL
GAS   see   Figure  9.2).    Apply
mixture of liquid soap and  water
to  gas  joints.  Bubbles forming
show  a  leak.

5.   Correct all leaks at once.
6.  Light  heater  (see    Operating

Heater). Check  all other internal
joints  for  leaks.

7.  Turn  off  heater (see To Turn Off
      Gas  Appliance).

       

  WARNING:

   Failure  to  position

the  parts  in  accordance  with  these
diagrams  or  failure  to  use  only  parts
specifically  approved  with  this  heater
may  result  in  property  damage  or
personal  injury.

       

  CAUTION:

    After  installation and

periodically  thereafter,  check  to en-
sure    th at    n o    flame    c omes    in
contact   with  any  log.  With  the  heater
set  to  High, check  to  see  if  flames
contact  any  log. If  so, reposition  logs
according    to  the  log    installation
instructions  in  this  manual. Flames

It is very important to install the logs
exactly as instructed. Do not modify
logs.  Only  use  logs  supplied  with
heater.

IMPORTANT

: Make  sure  log  does

not cover any burner ports (see Fig-
ure 10).
Also,  see  log  placing  instructions.

Figure  10 -Installing  Log  Set (Top  View)

Figure  9.2 -Checking Gas Joints

Test  Pressures  Equal  To  or
Less  Than  1/2  PSIG(3.5 kPa

)

1.    Close  equipment  shutoff  valve

(see Figure  8).

2.   Pressurize  supply  piping  system

by  either  using  compressed  air  or
opening    natural    supply    tank
valve.

3.   Check  all  joints  from  gas  meter  to

equ ipment    shutoff    valve(see
Figure  9). Apply  mixture  of  liquid
soap  and   water  to  gas  joints.
Bubbles  forming  show  a  leak.

4.   Correct  all  leaks  at  once.

INSTALLATION INSTRUCTIONS FOR LOG
PLACEMENT

1.    LOGS

FIG(1)

FIG(2)

STEP 1: Install  log 1 on the
left rear bracket .

STEP 2: Install log 2 on the

right rear bracket .

STEP 3: Install log 3  into slots on
the front bracket .

STEP 4: Place recessed hole  on the
bottom part of  log 5 onto the pin on  log
2. Place the lower part of log 5 on the flat

area at the right side of log 3  .

STEP 5: Place recessed hole on the
bottom part of  log 4  onto the pin on log
1. Place the lower part of log 4 on

the flat area at the left side of log 3 .

FIG(3)

FIG(4)

FIG(5)

FIG(6)

Summary of Contents for GSN2221

Page 1: ...n these instruction for future use WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be...

Page 2: ...nning heater Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the ra...

Page 3: ...m heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYS TEM This heater has a piezo ignitor This system requires no matches batteries or other sources to light...

Page 4: ...ATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater...

Page 5: ...fined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is...

Page 6: ...ter for proper type heater Figure 4 Minimum Clearance to Wall and Ceiling NOTICE This heater is intended for use as supplemental heat Use this heater along with your primary heating system Do not inst...

Page 7: ...make sure you have the items listed below l piping check local codes l sealant resistant to propane LP gas l equipment shutoff valve l test gauge connection l sediment trap l tee joint l pipe wrench l...

Page 8: ...controls If sediment trap is not installed or is installed incorrectly heater may not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting into gas piping and...

Page 9: ...structed Do not modify logs Only use logs supplied with heater IMPORTANT Make sure log does not cover any burner ports see Fig ure 10 Also see log placing instructions Figure 10 Installing Log Set Top...

Page 10: ...rom the fan to the Black Wire from the Switch Box and the other Black Wire to the White Wire Make sure these wires are clear of the fan Reattach the Back Panel using the 6 screws removed earlier Attac...

Page 11: ...1 1 Installing Blower Accessory BLOWER ACCESSORY 20 6028 OR 20 6029 Figure 15 F Mounting Blower And Installing Blower Control Housing Figure 14 F Routing Power Cord...

Page 12: ...12 column 1 If you don t smell gas go to the next step 6 Turn control knob counterclock wise to the PIILOT position Press in control knob for five 5 seconds see Figure 17 l Note You may be running thi...

Page 13: ...an burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit...

Page 14: ...e 74 lbs Shipping 83 lbs For purposes of input adjustment CABINET Air Passageways l Use a vacuum cleaner or pressurized air to clean Exterior l Use a soft cloth dampened with a mild soap and water mix...

Page 15: ...lot see Cleaning and Maintenance or replace ODS pilot assembly 7 Replace thermocouple 8 Replace control valve POSSIBLECAUSE 1 Ignitor electrode is positioned wrong 2 Ignitor electrode is broken 3 Igni...

Page 16: ...or partially clogged burner orifice 1 When heated vapors from furniture polish wax carpet cleaners etc turn into a white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance or r...

Page 17: ...LP gas company 3 Clean ODS pilot 1 Locate and correct all leaks s e e C h e c k i n g G a s Connections 2 Replace control valve 1 Take apart the gas tubing and remove the foreign matter 2 Locate and...

Page 18: ...2222 GSN2221 K E Y N O PA R T NO D E S C R IP TIO N Q TY N G Q TY LP G S N 3011 G S N 2221 G S N 3013 G S P 3012 G S P 2222 G S P 3014 1 Q L019 01 Le g 1 1 Q L019 02 Le g 1 1 Q L019 01B Le g 1 Q L019...

Page 19: ...3 GSP3012 GSP2222 GSP3014 1 BL037 02 Log set 1 1 1 1 1 1 2 BL038 02 Log set 1 1 1 1 1 1 3 BL039 02 Log set 1 1 1 1 1 1 4 BL040 02 Log set 1 1 1 1 1 1 5 BL041 02 Log set 1 1 1 1 1 1 6 ND1703X400X4 ODS...

Reviews: