Kozy-World GFN4113 Owner'S Operation & Installation Manual Download Page 3

                                  3

8.   This heater is designed to be
       smokeless. If logs ever appear to
       smoke, turn off  heater and call a
       qualified service person.
       Note: During initial operation, slight
       smoking could occur due to log
       curing and heater burning manufac
       turing residues.
9.   To prevent the creation of soot,
       follow the instructions in 

Cleaning

       and Maintenance(page 13).

10. Before using furniture polish, wax,
       carpet cleaner, or similar products,
       turn heater off. If heated, the vapors
       from these products may create a
       white powder residue within burner
       box or on adjacent walls or furniture.
11. This heater needs fresh air ventila-
       tion to run properly. This heater has
      an Oxygen Depletion Sensing
      (ODS) safety shutoff system.
      The ODS shuts down the heater if not
       enough fresh air is available. See 

Air for

       Combustion and Ventilation,

 pages 5

       through 6. If heater keeps shutting off,
       see 

Troubleshooting

,  pages 16

       through  17.
12. Do not run heater:

    l 

Where flammable liquids or

                 vapors  are used or stored.

   l 

Under  dusty  conditions.

       13. Do not use this heater to cook

       food or burn paper or other objects.
14. Do not use this heater if any part

              has been under water. lmmedia-
              tely call a qualified service techni-
              cian to  inspect the room heater.

SAFETY  INFORMATION

Continued

QUALIFIED INSTALLING AGENCY

Installation and  replacement  of  gas
piping, gas utilization equipment or ac-
cessories and repair and servicing of
equipment shall be performed only by
a qualified agency. The term 

qualified

agency

  means any  individual,  firm,

corporation, or company that either in
person or through a representative is
engaged in and is responsible for (a)
the installation,testing,or replacement
of  gas  piping  or(b)the  connection,
installation,testing,repair,or servicing
of equipment; that is experienced in
such work; that is familiar with all pre-
cautions required,and that has com-
plied with all the requirement of  the
authorty having jurisdiction.

15.  Turn off and unplug heater and
        let cool before servicing. Only a

qualified service person should
service and repair heater.

16.  Operating heater above
        elevations.

18.  To prevent performance
        problems, do not use propane/
        LP fuel tank of less than 100 lbs.
        capacity.

PRODUCT  FEATURES

SAFETY  PILOT

This heater has a pilot with an
Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot
is a required feature for vent-free
room heaters. The ODS/pilot shuts
off the heater if  there is not enough
fresh air.

MANUAL OVERRIDE CONTROL SYS-
TEM  (GFN4227R, GFP4228R Series)

This  heater  has  two  operation
functions: Remote Control and Manual
Override Control. The Remote Control
has a transmitter, which requires three

AAA

  batteries and electric power

outlet to operate. If no electric power
is available, then you can operate the
heater by manual override.
The ignitor require one 

AAA

  battery.

State of Massachusetts:

 The instal-

lation  must  be made by a licensed
plumber or gas fitter in the Common-
wealth of Massachusetts.
Sellers of unvented propane or natu-
ral gas-fired supplemental room heat-
ers shall provide to each purchaser a
copy of 527 CMR 30 upon sale of the
unit.
In   th e  state  of  Massachusetts,
unvented propane or natural gas-fired
space heaters shall be prohibited in
bedrooms and bathrooms.

In the State of Massachusetts the
gas cock must be a 

T

 handle type.

The  State  of  Massachusetts re-
quires that a flexible appliance con-
nector cannot exceed three feet in
length.

17.  Do not operate heater if any log
        is broken. Do not operate heater
        if any log is chipped (dime-sized
        or larger).of 4,500 feet could
        cause pilot outage.

3

Summary of Contents for GFN4113

Page 1: ...liance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases GFN4311 GFP4312 GFN4113 GFP4114 GFP4306 GFN4305 GFN4227R GFP4228R W...

Page 2: ...aterials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rat ing plate This appliance is not con vertible for use with other gase...

Page 3: ...connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all pre cautions required and that has com plied with all the requirement of the...

Page 4: ...al heat applications the water vapor does not creat a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help in...

Page 5: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Page 6: ...re 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space When v...

Page 7: ...smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater i...

Page 8: ...re for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells...

Page 9: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints CH...

Page 10: ...ll the logs exactly as instructed Do not modify logs Only use logs supplied wall heater IMPORTANT Make sure log does not cover any burner ports see Figure 10 Figure 10 Installing Log Set FIG 1 FIG 2 S...

Page 11: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the the appli ance could no...

Page 12: ...thirty 30 seconds This will allow air to bleed from the gas system 7 With Control Knob pressed in push ignitor button This will light the pilot If needed keep ignitor button until pilot lights MANUAL...

Page 13: ...n disconne ct two wires free to fan 2 Mark or tag each wire removed for its exact reconnection Remove the four screws from the fan when installing reverse the steps above See Figure 20 and Figure 23 F...

Page 14: ...the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air hol...

Page 15: ...eater 44 3 16 46 7 8 16 5 8 44 3 16 46 7 8 16 5 8 Carton 44 7 8 51 20 7 8 44 7 8 51 20 7 8 Weight lbs Stove 265 265 Shipping 295 295 GFN4311 GFN4305 GFP4306 GFP4312 Dimensions Inches H W D Heater 45 5...

Page 16: ...ot unit Spark at ODS pilot but no ignition 1 Gas supply turned off or equip ment shut off valve closed 2 Air in gas lines when installed 3 Depleted gas supply 4 ODS pilot is clogged 5 Gas regulator se...

Page 17: ...l Your name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used propane LP or NG l Purchase date REPLACEMENT PARTS l Warranty card Usually we w...

Page 18: ...ER ASSEMBLY 1 ND1703X400 ODS 1 ND1908X400 ODS 1 6 FBB504 ODS INLET TUBE ASSEMBLY 1 1 7 FBB502 INLET TUBE ASSEMBLY 1 1 8 FBB503 OUTLET TUBE ASSEMBLY 1 1 QUALITY KEY NO PART NUMBER DESCRIPTION 5 1 2 3 4...

Page 19: ...05A5M SIDE PANEL 1 1 5 FB 03A5M BASE 1 1 6 FB 02A5M UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FHL008 02 BAFFLE 1 1 10 FHL021 022 02 SIDE REFLECTOR 2 2 11 FHL007 02...

Page 20: ...IDE PANEL 1 1 5 FB 03AM BASE 1 1 6 FB 02AM UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FhL008 02 BAFFLE 1 1 10 FhL021 022 02 SIDE REFLECTOR 1 1 11 FhL007 02B FIREBOX...

Page 21: ...LATOR 1 NRV82FB 9 REGULATOR 1 ND4703X400 RHN ODS 1 ND4908X400 RHN ODS 1 NB40 032H BURNER ASSEMBLY 1 NB40 140H BURNER ASSEMBLY 1 HL036 02 INJECTOR 1 HL036 01 INJECTOR 1 9 FBB320RH OUTLET TUBE ASSEMBLY...

Page 22: ...PANEL 1 1 6 FhL001 01 01 BODY TOP COVER 1 1 7 FhL001 02 01 BODY BOARDING 1 1 8 FhL021 022 02 SIDE REFLECTOR 2 2 9 FhL007 02B FIREBOX FLOOR 1 1 10 FhL001 03 BODY BOTTOM COVER 1 1 11 BL016 07 BLOWER MO...

Reviews: