Kozy-World GFN4113 Owner'S Operation & Installation Manual Download Page 21

                                                                        2 1

PARTS  LIST

GFN4227R
GFN4228R

LP NG

1

2020-22

OVERRIDE CONTROL SYSTEM

1

1

2

FHL031-01R

DOUBLE CONTROL VALVE BRACKERT

1

1

3

FBB330RH

ODS INLET TUBE ASSEMBLY

1

1

4

FBB310RH

INLET TUBE ASSEMBLY

1

1

NRV82FB-4

REGULATOR

1

NRV82FB-9

REGULATOR

1

       ND4703X400-RHN

ODS

1

       ND4908X400-RHN

ODS

1

NB40-032H

BURNER ASSEMBLY

1

NB40-140H

BURNER ASSEMBLY

1

HL036-02

INJECTOR

1

HL036-01

INJECTOR

1

9

FBB320RH

OUTLET TUBE ASSEMBLY

1

1

QUALITY

KEY NO

PART NUMBER

DESCRIPTION

8

5

6

7

This  list  contains  replaceable  parts  used  in  your  heater. When  ordering
parts, follow  the  instructions  listed  under  

Replacement Parts

 on page 17

of   this  manual.

21

Summary of Contents for GFN4113

Page 1: ...liance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases GFN4311 GFP4312 GFN4113 GFP4114 GFP4306 GFN4305 GFN4227R GFP4228R W...

Page 2: ...aterials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rat ing plate This appliance is not con vertible for use with other gase...

Page 3: ...connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all pre cautions required and that has com plied with all the requirement of the...

Page 4: ...al heat applications the water vapor does not creat a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help in...

Page 5: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Page 6: ...re 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space When v...

Page 7: ...smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater i...

Page 8: ...re for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells...

Page 9: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints CH...

Page 10: ...ll the logs exactly as instructed Do not modify logs Only use logs supplied wall heater IMPORTANT Make sure log does not cover any burner ports see Figure 10 Figure 10 Installing Log Set FIG 1 FIG 2 S...

Page 11: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the the appli ance could no...

Page 12: ...thirty 30 seconds This will allow air to bleed from the gas system 7 With Control Knob pressed in push ignitor button This will light the pilot If needed keep ignitor button until pilot lights MANUAL...

Page 13: ...n disconne ct two wires free to fan 2 Mark or tag each wire removed for its exact reconnection Remove the four screws from the fan when installing reverse the steps above See Figure 20 and Figure 23 F...

Page 14: ...the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air hol...

Page 15: ...eater 44 3 16 46 7 8 16 5 8 44 3 16 46 7 8 16 5 8 Carton 44 7 8 51 20 7 8 44 7 8 51 20 7 8 Weight lbs Stove 265 265 Shipping 295 295 GFN4311 GFN4305 GFP4306 GFP4312 Dimensions Inches H W D Heater 45 5...

Page 16: ...ot unit Spark at ODS pilot but no ignition 1 Gas supply turned off or equip ment shut off valve closed 2 Air in gas lines when installed 3 Depleted gas supply 4 ODS pilot is clogged 5 Gas regulator se...

Page 17: ...l Your name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used propane LP or NG l Purchase date REPLACEMENT PARTS l Warranty card Usually we w...

Page 18: ...ER ASSEMBLY 1 ND1703X400 ODS 1 ND1908X400 ODS 1 6 FBB504 ODS INLET TUBE ASSEMBLY 1 1 7 FBB502 INLET TUBE ASSEMBLY 1 1 8 FBB503 OUTLET TUBE ASSEMBLY 1 1 QUALITY KEY NO PART NUMBER DESCRIPTION 5 1 2 3 4...

Page 19: ...05A5M SIDE PANEL 1 1 5 FB 03A5M BASE 1 1 6 FB 02A5M UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FHL008 02 BAFFLE 1 1 10 FHL021 022 02 SIDE REFLECTOR 2 2 11 FHL007 02...

Page 20: ...IDE PANEL 1 1 5 FB 03AM BASE 1 1 6 FB 02AM UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FhL008 02 BAFFLE 1 1 10 FhL021 022 02 SIDE REFLECTOR 1 1 11 FhL007 02B FIREBOX...

Page 21: ...LATOR 1 NRV82FB 9 REGULATOR 1 ND4703X400 RHN ODS 1 ND4908X400 RHN ODS 1 NB40 032H BURNER ASSEMBLY 1 NB40 140H BURNER ASSEMBLY 1 HL036 02 INJECTOR 1 HL036 01 INJECTOR 1 9 FBB320RH OUTLET TUBE ASSEMBLY...

Page 22: ...PANEL 1 1 6 FhL001 01 01 BODY TOP COVER 1 1 7 FhL001 02 01 BODY BOARDING 1 1 8 FhL021 022 02 SIDE REFLECTOR 2 2 9 FhL007 02B FIREBOX FLOOR 1 1 10 FhL001 03 BODY BOTTOM COVER 1 1 11 BL016 07 BLOWER MO...