Kozy-World FBD2810T Manual Download Page 12

12

Fig. 8 - Rough Opening for Installing in Corner

IMPORTANT

: When finishing your firebox, combustible 

materials such as wall board, gypsum board, sheet rock, 

drywall, plywood, etc, must have ½ -in. clearance to the sides 

and top of the firebox. Combustible materials should never 

overlap the firebox front.

 WARNING

: Do not allow any combustible materials to 

        overlap the firebox front.

 WARNING

: Do not allow combustible or noncombustible 

        materials to cover any necessary openings like louvered 

        slots.

 WARNING

: Never modify or cover the louvered slots on 

        the front of the firebox.

Step 1

Step 3

Step 2

Fig 9

Remove two

screws on top

firebox panel

Insert three 

screws on 

hood

Assembling Hood

 CAUTION

: Do not operate fireplace without hood in place.

1. Fireplace hood is positioned on top of shipping inner pack.

2. Remove top of firebox by unscrewing two screws located 

    on each end. Insert the hood along the upper side of the 

    heat insulation board (see Fig. 9). Attach the hood with 

   3 screws. Re-attach the firebox top by re-inserting the two 

   screws.

Summary of Contents for FBD2810T

Page 1: ...his manual with the appliance CONSUMER Retain this manual for future reference WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE...

Page 2: ...arting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS Model FBD28T VENT FREE GAS FIREPLACE INSERT Input Rating...

Page 3: ...sory not approved for use with this heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable materi...

Page 4: ...d items can cause sooting Do not add lava rock around base Rock and debris could fall into the control area of heater After servicing always replace screen before operating heater 16 This heater is de...

Page 5: ...sed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale...

Page 6: ...of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In most supplemental...

Page 7: ...art of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining...

Page 8: ...ter logs ________ BTU hr Gas water heater 30 000 BTU hr Other gas appliances ___BTU hr Vent free heater 26 000 BTU hr Total ________________ BTU hr Total 56 000 BTU hr Do not include direct vent gas a...

Page 9: ...ing to an adjoining unconfined space you must provide two permanent openings one within 12 inches of the wall connecting the two spaces see options 1 and 2 Fig 2 You can also remove door into adjoinin...

Page 10: ...tc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free h...

Page 11: ...ons shown in Fig 8 for the rough opening The height is 26 1 2 in which is the same as the wall opening above 2 Carefully set fireplace in front of rough opening with back of fireplace inside wall open...

Page 12: ...ombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the firebox Step 1 Step 3 Step 2 Fig 9 Remove two screws on to...

Page 13: ...cceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This ga...

Page 14: ...end that you install a sediment trap in a supply line as shown in Fig 12 Locate sediment trap where it is within reach for cleaning and not likely to freeze Install in the piping system between fuel s...

Page 15: ...rter and turn knob clockwise until the knob locks into the NG position see Fig 14 3 Rotate and close cover over fuel selection device and reinstall screw 4 Remove steel or metal hex plug with wrench p...

Page 16: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig 16 2 Pressure supply...

Page 17: ...ns in this manual Flames contacting logs will create soot Fig 18 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Fig 18 It is very important to install the logs exactly...

Page 18: ...ap and install a AAA battery with the pointing out Replace cap 1 STOP Read the safety information on page 18 2 Warning You must operate this heater with the screen in place Make sure screen is install...

Page 19: ...ote The thermostat sensing bulb measures the temperature depending on housing construction TO TURN OFF GAS TO APPLIANCE Shut off heater Turn Control Knob clockwise to the OFF position Do not force MAN...

Page 20: ...ame Pattern Fig 22 Correct Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 23 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 21 Incorrect Pilot Flame Pattern BUR...

Page 21: ...pet hair etc The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt and lint Clean these air inlet hole...

Page 22: ...Depleted gas supply 1 Turn on gas supply or open equipment shutoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down control knob for 30 seconds to remove air R...

Page 23: ...ct qualified service technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white...

Page 24: ...ZY WORLD PHONE NUMBER 800 776 9425 When contacting your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used natural or propa...

Page 25: ...B 10 Fuel Selection Device Assembly YDF06 FBD28T 11 Hood FB28D04 B 12 Logs Set FB28D500 C 13 Log 1 FB28D501 C 14 Log 2 BL037 02 B 15 Log 3 BL038 02 B 16 Log 4 BL041 02 17 Log 5 FB28D505 C 18 Screen F...