A. Gas control knob not turned to „ON‟.
B. „ON‟/„OFF‟ switch not turned on.
C. Remote, wall switch or thermostat not turned „ON‟.
D. Plugged main burner orifice.
E. Remote, wall switch, thermostat or „ON/ OFF‟ switch wires defective.
♦ Check wires for proper connections. Place jumper wires across terminal at switch. If burner lights, replace defective swit
ch.
♦ If switch checks ok, place jumper wires across switch wires on gas valve. If burner lights, wires are faulty or connection
s are bad.
TROUBLESHOOTING
BURNER WILL NOT LIGHT
FREQUENT PILOT OUTAGES
A. Pilot shield not installed.
B. Pilot flame too high or too low, causing pilot safety to drop out.
♦ Clean and adjust flame for maximum flame impingement on thermopile.
BURNER WON‟T STAY LIT
A. Thermopile wires loose at valve terminals.
♦ Tighten if necessary.
B. Thermopile wires ground out due to pinched wires.
♦ Free pinched wires if necessary.
C
Refractory panel placement.
♦ Refractory panels must be tight against firebox walls. It may be necessary to secure panels with high
-temp sealant, especially around
the intake duct.