kozy heat Windim-WDM 56101 Installation And Operation Manual Download Page 15

1.  Insert fans through the lower grill opening, push to the back, posi-

tioning as far apart as possible.  
 

2.  Connect fan wiring by attaching connectors on right fan onto termi-

nals on left fan. 
 

3.  Insert 110V-120V wiring (with ground) through romex connector 

and wire to the speed control / receptacle assembly, matching the 
black (hot), white (neutral), and green (ground) wires to the corre-
sponding wires on the speed control / receptacle assembly.  
 

 
 

4.  Secure speed control / receptacle assembly to the electrical box with  

(2) screws provided.  
 
 

5.  Re-install electrical access panel. Tighten screws. 

 

6.  Attach the temperature control switch to the bottom of firebox.  

 

7.  Plug cord into the electrical box receptacle.  

 

8.  Turn speed control counter-

clockwise until it „clicks‟.  This is the 

„OFF‟ position.

 

 

9. 

Turn speed control „ON‟ by turning knob clockwise past the „click‟ 

- this is the highest setting. 
 

10.  Re-install lower grill. Refer to page 26 of this installation manual if 

necessary. 

NOTE: Speed control / receptacle assembly & (3) wire nuts 
are included in the fireplace components packet. 

Before  adjusting  the  temperature  control  switch,  unplug  the  3-prong 
plug  on  the  fan  cord  from  the  receptacle.    Adjust  position  of  the  tem-
perature  control  switch  to  a  warmer  location  under  the  firebox  to  turn  

fan „ON‟ sooner or move it to a cooler location under firebox to turn the 
fan „ON‟ later. The fan will turn on when the sensor in the temperature 
control  switch  reaches  110°  F  and  will  turn  „OFF‟  when  the  sensor 

reaches 90° F. After adjustment, plug the 3-prong plug on fan cord into 
the receptacle

                        OPTIONAL FAN  INSTALLATION  

PAGE 14 

NOTE: This appliance must be electrically grounded and connected 
in accordance with local codes, or in the absence of local codes, with 
the National Electrical Code, ANSI/NFPA 70 Current Edition, or  

 

        the Canadian electrical Code CSA C22.1. 

NOTE: This fan will not operate unless the speed control has been turned 
„ON‟ and sufficient heat has been applied to the temperature control switch.  
The fan will turn „ON‟ and „OFF‟ automatically as the fireplace heats and 
cools. Adjust fan to desired speed while it is running. 

TEMPERATURE CONTROL SWITCH POSITION

 

Temperature Control Switch  (Looking through lower grill opening). 

Connect fan wiring 

Summary of Contents for Windim-WDM 56101

Page 1: ...f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these...

Page 2: ...ourselves in being dedicated to not only function and reliability but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from you...

Page 3: ...nting 17 Horizontal Vent System Clearances 17 VENTING cont Min Max Horizontal Vent System Information 17 Vertical Vent System Clearances 17 Min Max Vertical Vent System Information 17 Horizontal Verti...

Page 4: ...appliance should be located out of traffic and away from furniture and draperies The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work...

Page 5: ...eless wall mount thermostat Decorative full door faces screen doors in various styles and finishes Rectangular valance Interior Exterior trim Various grill designs and finishes Each unit factory teste...

Page 6: ...eet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print no less the one half inch 1 2 in size...

Page 7: ...279 495 51 568 108 121 70 SPECIFICATIONS NOTE OTHER CLEARANCES APPLY ALL CLEARANCES MUST BE MAINTAINED CAUTION STAND OFF BRACKETS ARE NOT LOAD BEARING PAGE 6 FRONT RIGHT 32 812mm 11 279mm 19 1 2 495mm...

Page 8: ...BRACKETS MUST BE ATTACHED TO FIREPLACE DO NOT REMOVE CLEARANCES NOTE OTHER CLEARANCES APPLY ALL CLEARANCES MUST BE MAINTAINED CAUTION STAND OFF BRACKETS ARE NOT LOAD BEARING 1 25 mm clearance 1 25 mm...

Page 9: ...25 mm clearance at sides 1 25 mm clearance at sides 1 25 mm clearance at sides 1 25 mm 2 1 4 57 mm 32 813 mm 5 1 4 133 mm 37 3 4 959 mm 1 25 mm 2 1 4 57 mm 5 1 2 140 mm 38 3 8 975 mm 32 5 8 829 mm NO...

Page 10: ...stallation 9 Secure fireplace to flooring through holes located in the outer box bottom and to framing with nailing flanges Verify all clearances at this point 10 Install facing material mantel or cab...

Page 11: ...LE FACING MATERIAL MAY BE APPLIED OVER BUT NOT DIRECTLY TO FIREPLACE FACE THIS WILL PREVENT THE FACING MATERIAL FROM FALLING OFF DUE TO EXPANSION OF THE FACE WHEN HEATED DO NOT OBSTRUCT THE FLOW OF VE...

Page 12: ...nimum venting requirements a minimum of 26 660 mm from the floor or hearth the fireplace is setting on to the top of vent pipe is required IMPORTANT WALL PASS THRU REQUIRED FOR ALL HORIZONTAL RUNS REF...

Page 13: ...oving glass frame assembly CAUTION NEVER PERMANENTLY REMOVE THESE ASSEMBLIES FROM THE FIREPLACE THEY MUST BE SECURED IN PLACE REGARDLESS OF FINISH MATERIAL USED FRAMING STUD NAILING FLANGE FRAMING STU...

Page 14: ...electrical codes for specific requirements WARNING THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROU...

Page 15: ...included in the fireplace components packet Before adjusting the temperature control switch unplug the 3 prong plug on the fan cord from the receptacle Adjust position of the tem perature control swit...

Page 16: ...EFFICIENCY 69 11 66 23 AFUE 68 41 65 3 P 4 AFE 56 1 55 53 IMPORTANT The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating condi tions...

Page 17: ...st be placed over the remote receiver to prevent over heating IMPORTANT If ON OFF rocker switch wires are not disconnected the ON OFF rocker switch on the millivolt board must be in the OFF position f...

Page 18: ...TOP BOTTOM SIDES 1 1 2 inches 38 mm at wall pass thru 1 inch 25 mm 1 inch 25 mm HORIZONTAL TERMINATIONS MINIMUM 6 152 mm horizontal termination cap MAXIMUM 20 ft 6 096 m horizontal termination cap VEN...

Page 19: ...ee angles to create tension to hold itself in place when installed Remove tab s to create small restrictor Slide restrictor into exhaust pipe at back of fireplace with tabs pointing towards you prior...

Page 20: ...gas application if desired 45 ELBOW 90 ELBOW 90 ELBOW PAGE 19 CAUTION This gas appliance must not be connected to or joined with any other chimney flue serving another appliance WARNING A WALL PASS T...

Page 21: ...n conjunction with venting installation Page 33 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed MAXIMUM V...

Page 22: ...ed above a gas meter regulator assembly within 3 ft 914 mm horizontally from the centerline of the regulator J Non mechanical air supply inlet to building or the combustion air inlet to any other appl...

Page 23: ...ROOF PITCH X 12 H minimum MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING APPROVED CAP APPROVED VENT PIPE DISCHARGE OPENING 8 MIN IF VENT IS CLOSER THAN 8 IT MUST TERMINATE AT LEAST 2 HIGHER THA...

Page 24: ...ition W8 W9 W10 logs aligning to notches in base logs Position base log W5 by aligning cut out over pilot assembly and slots in bottom of log over burner cover brackets Press down slightly to secure i...

Page 25: ...logs 7 Remove burner tube by lifting up and off tabs sliding to the left off of burner orifice 8 Remove burner plate 9 Remove 6 nuts securing millivolt board to firebox bottom mounting studs 10 Lift...

Page 26: ...nect gas line to manual shut off valve 6 Reconnect any wall switch remote control or thermostat wires to the top bottom terminals on gas valve 7 Reinstall glass frame assembly Page 12 8 Reinstall uppe...

Page 27: ...out of opening B Remove nuts securing lower grill to hinges Remove from fireplace Reattach nuts to grill GRILL SET purchased separately PAGE 26 UPPER LOWER GRILL INSTALLATION REMOVAL INSTALLATION REMO...

Page 28: ...56101 VALVE PILOT ASSEMBLY COMPONENTS PAGE 27 ELECTRODE PILOT HOOD THERMOPILE THERMOCOUPLE VALVE TERMINALS GAS CONTROL KNOB PIEZO IGNITOR HI LO FLAME ADJUSTMENT KNOB ON OFF ROCKER SWITCH...

Page 29: ...E DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN CLOTHING AND FURNITURE AWAY This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and...

Page 30: ...nformation on the front cover and on the previous page of this installa tion manual If you don t smell gas go to the next step B Locate pilot follow metal tube from gas control The pilot is located in...

Page 31: ...p off wall switch or adjust setting on the thermostat or remote control NOTE The pilot will stay lit H Turn the pilot off by pushing in and turning the gas control knob to the OFF position DO NOT FORC...

Page 32: ...switch to OFF 7 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Attach manometer to manifold pressure tap to verify that it is completely sealed Manome...

Page 33: ...r Dark orange flame with black tips Open venturi setting slightly Open too far Blue flames Close venturi setting slightly NOTE IF SOOT IS PRESENT CHECK LOG POSITIONING BEFORE ADJUSTING BURNER VENTURI...

Page 34: ...ication is necessary remove restrictor by pulling it down and out of 4 exhaust pipe 5 Reinstall baffle by resting baffle front above flange along inside top of firebox opening Tip baffle backwards aga...

Page 35: ...SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALI FIED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT F...

Page 36: ...ONS A Check that pilot flame impinges on thermocouple Clean and or adjust pilot for maximum flame impingement B Ensure the thermocouple connection at gas valve is fully inserted and tight hand tight p...

Page 37: ...r connections are bad TROUBLESHOOTING BURNER WILL NOT LIGHT FREQUENT PILOT OUTAGES A Pilot shield not installed B Pilot flame too high or too low causing pilot safety to drop out Clean and adjust flam...

Page 38: ...rizontal vent 1 4 6 mm rise per foot is required on horizontal venting E Inner vent pipe leaking exhaust gases back into firebox Check for leaks Repair if necessary F Improper vent cap installation Ch...

Page 39: ...bing Valve to Pilot OCK S55A LP Gas Conversion Kit 700 092 Millivolt Generator 700 098 Pilot Hood 700 092 Thermocouple OKA 035 Burner Tube Consult your dealer for information on optional accessories a...

Page 40: ...PAGE 39...

Page 41: ...PAGE 40...

Reviews: