45
Improper glass media placement. Refer to 13.4, Glass Media, on page 31.
Improper venturi setting. Venturi may need to be opened slightly to allow more air into the gas mix. Refer to 18.2, Burner
Tube Venturi, on page 42.
Improper pitch on horizontal venting. 1/4 in. (6 mm) rise per foot required on horizontal venting.
Improper venturi setting. Venturi may need to be closed slightly. Refer to 18.2, Burner Tube Venturi, on page 42.
Improper vent cap installation. Check for proper vent cap installation.
Blockage or leakage of the vent system.
Backup battery pack batteries or remote control batteries low. Replace batteries.
No communication between remote control and IFC control module. Reprogram remote control to IFC control module.
Follow 15.2, Initialize the Control System for the First Time, on page 34.
A maximum number of failed ignitions or flame restorations has been reached. Reset IFC control module.
No LP in tank. Check and refill if necessary.
Glass frame assembly not installed correctly. Refer to 13.1, Glass Frame Assembly, page 29.
Improper vent cap installation. Adjust if necessary.
Vent cap blockage. Remove debris if necessary.
Improper pitch on horizontal venting. 1/4 in. (6 mm) rise per foot is required on horizontal venting.
Inner vent pipe leaking exhaust gases back into the firebox. Check for leaks, and repair if necessary.
Excessive draft.
19.4
Pilot and Burner Extinguish While in Operation
19.5
Glass Sooting
19.6
Flame Burns Blue and Lifts Off Burner
19.7
No Reaction to Command
Reset Using ON/OFF Switch:
Set ON/OFF switch to OFF position.
Wait approximately (2) seconds and move switch to the ON position. The ignition sequence will start again.
Reset Using Remote Control ON/OFF Button:
Turn the system off by pressing the remote control ON/OFF button.
After approximately (2) seconds press the remote control ON/OFF button again. The IFC control module will reset and the
ignition sequence will start again.
Reset By Cycling Flame
:
In the Manual Flame Control Mode, use the Down Arrow Button to reduce flame to off (indicated by OFF displayed on
Remote Control Display Screen).
Wait approximately (2) seconds and press the Up Arrow Button, the ignition sequence will start.
19.7.1
Reset IFC Control Module
—
Lock Out