background image

#RVT-29-BW R.2 July 2018

Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

LIMITED LIFETIME WARRANTY 

39

LIMITED LIFETIME WARRANTY

Warranty Coverage

Hussong Manufacturing Company, Inc. (Hussong Mfg.) warrants this 

Kozy Heat gas appliance from the date of purchase to the original 

purchaser, that it is free of defects in materials and workmanship at 

the time of manufacture. Registering your fireplace warranty does not 

require any documents to be sent in to Hussong Mfg. Please retain 

your proof of purchase reflecting the date of purchase along with the 

serial number and model of your fireplace for any future warranty 

claims.

If a defect is noted within the warranty period, the customer should 

contact their authorized dealer for service within 30 days.

30 Days: Parts & Labor*

• 

Paint

• 

Light bulbs

• 

Gasket material 

• 

Glass media and media dam

Year 1: Parts & Labor*

• 

All parts and material except the items listed in the 30 day 

warranty and any exclusions or limitations that may apply.

*Hussong Mfg. will issue labor reimbursement to an authorized dealer 

only. Hussong Mfg. will not be liable for charges occurred as a result of 

any service performed by a non-authorized service provider, without 

pre-authorization. 

Years 2 through Lifetime: Parts Only

• 

Firebox

• 

Heat Exchanger

• 

Logs

• 

Burner tube or pan

• 

Outer shell

• 

Heat shield(s)

• 

Front Viewing Glass (thermal shock only)

• 

Refractory Firebox liner (excluding enamel and glass panels)

EXCLUSIONS AND LIMITATIONS

1.  This appliance must be installed by a licensed, authorized service technician or contractor. It must be installed, operated and maintained 

at all times in accordance with the instructions in the owner’s manual or the warranty is void.

2.  This warranty is nontransferable and is made to the original purchaser only.
3.  This warranty excludes standard wear and tear of the appliance which is considered normal usage over time.
4.  Discoloration and some minor expansion, contraction or movement of certain parts, resulting in noise, is normal and not a defect.
5.  Warranty is automatically voided if the appliance’s serial number and/or testing label is removed or if the appliance is altered or 

tampered with in any way.

6.  Warranty is void if the appliance is subject to submersion in water or prolonged periods of dampness or condensation. Any damage 

to any part of the appliance due to water or weather damage which is the result of, but not limited to, improper chimney/venting 

installation will also render this warranty void.

7.  This warranty does not cover installation and operational related problems such as environmental conditions, nearby trees, buildings, 

hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by any mechanical systems.

8.  Chimney components and other Non-Hussong Mfg. accessories used in conjunction with the installation of this appliance are not 

covered under this warranty.

9.  Damage to plated surfaces or accessories, if applicable, caused by scratches, fingerprints, melted items or other external sources left on 

the surfaces from the use of cleaners is not covered under this warranty.

10.  It is expressly agreed and understood that this warranty is Hussong Mfg.’s sole obligation and purchaser’s exclusive remedy for defective 

fireplace equipment. Hussong Mfg. is free of liability for any damages caused by this appliance, as well as inconvenience expenses 

and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or 

consequential damage may not apply. Hussong Mfg. shall not be held to implied warranties and this warranty shall replace all previous 

warranties.

11.  This limited lifetime warranty is the only warranty supplied by Hussong Mfg. Any warranties extended to the purchaser by the dealer/

distributor, whether expressed or implied, are hereby disclaimed and the purchaser’s recourse is expressly limited to the warranties set 

forth herein.

12.  Any part repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period 

not to exceed the remaining term of the original limited warranty.

13.  Any replacement part repaired after the warranty period will include a 90 day parts coverage
14.  Hussong Mfg. may require the defective part to be returned using a pre-authorized RGA number or a photo of the defective component. 

Failure to provide either can result in a denied claim.

15.  This warranty does not cover the appliances ability to heat a desired space, as there are many factors that can impact the heating 

performance in each home. Consideration should be implied to the appliance’s location, room size, home design, environmental 

conditions, insulation, and tightness of the home.

16.  Hussong Mfg. reserves the right to make changes at any time, without notice, in design, material, specifications, and prices. Hussong 

Mfg. reserves the right to discontinue models and products.

July 2018

Summary of Contents for ROOSEVELT 29 BW

Page 1: ...manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for u...

Page 2: ......

Page 3: ...being dedicated not only to functionality and reliability but also customer safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat...

Page 4: ......

Page 5: ...ace and Secure Appliance 17 7 0 GAS LINE CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Insta...

Page 6: ......

Page 7: ...y period a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above pr...

Page 8: ...e installed at higher altitudes Please refer to National Fuel Gas Code ANSI Z223 1 NFPA 54 CSA B149 1 Natural Gas and Propane Installation Code local authorities or codes having jurisdiction in you ar...

Page 9: ...TIONS 9 2 2 Appliance Dimensions Figure 2 1 Appliance Dimensions 201 16 510mm 16 406mm 2711 16 703mm 295 8 753mm 197 8 505mm 1715 16 456mm 13 16 31mm 14 356mm 6 172mm 11 8 28mm 129 16 319mm 33 16 81mm...

Page 10: ...roved parts with this appliance may result in property damage or personal injury Figure 2 2 Proper Positioning of Appliance Table 2 1 Field Assembled Parts A Fireplace insert G Burner air flow plate B...

Page 11: ...th Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used IMPORTANT Consider the height of hearth finish material when building a fireplace platform Proper ins...

Page 12: ...D label at bottom of existing firebox so it will be visible if this gas fireplace insert is removed 3 2 1 1 Existing Fireplace Opening Minimum Requirements If installing the RT29 FLP add 3 4 19mm tota...

Page 13: ...1 Vent Termination Clearances WARNING This appliance must not share or be connected to a chimney flue serving any other appliance Approved vent caps require 12 in 305mm clearance to intersecting wall...

Page 14: ...ce has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner The access hole must be...

Page 15: ...y cause abrasion or damage to the flexible pipes 1 Measure the total chimney length required and cut 816 36 10 97m of 3 flexible pipe to the measured length 2 Carefully extend the exhaust and combusti...

Page 16: ...through the chimney place unfaced insulation around the first 3 ft 914 mm of vent system below termination cap Secure with wire 2 Install the 3 x 3 flexible pipes down through existing chimney Guide...

Page 17: ...appliance is properly positioned Figure 6 4 Aligned Insert 6 5 Connect Vent Pipe to Vent Adapter IMPORTANT Proper operation of this insert requires the exhaust pipe and combustion air pipe to be conne...

Page 18: ...m tee handle manual shut off valve and flexible gas connector are to be connected to the in 13 mm control valve inlet If substituting for these components please consult local codes for compliance If...

Page 19: ...Clearances to Combustibles IMPORTANT Adequate accessibility clearances for servicing and proper operation must be maintained COMBUSTIBLE MATERIAL 4 102mm 12 305mm 9 229mm 11 286mm 8 210mm 281 8 714mm...

Page 20: ...Align leg section holes on the shroud to the corresponding mounting nuts in mounting brackets on each side of the insert metal cabinet 3 Secure with 4 phillips truss head screws provided 4 Reinstall...

Page 21: ...s assembly into position 2 Using the glass latch tool pull latches out and down over latch tabs to secure glass frame assembly bottom 9 2 Light Kit CAUTION Disconnect all electrical power from the fir...

Page 22: ...along the front of the plate positions at the bottom of the firebox Tilt the bottom of the plate in first The plates will install along the side of the burner and sit on the firebox floor 2 Install t...

Page 23: ...nversion before installing the log set Follow the conversion instructions included with the kit Log numbers located on the bottom of each log Refer to following instructions and illustrations for prop...

Page 24: ...ol board on the left side of the firebox 12 Pull out control board out to reveal gas line to disconnect the gas line flex tube from fireplace valve 9 5 2 Control Board Installation 1 Place control boa...

Page 25: ...ceptacle Do not cut or remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the abs...

Page 26: ...an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Locate the manual valve installed by your qualified service technician 6 Turn the manual valve clockwis...

Page 27: ...control operation of the main burner and fireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the remote sync button on the IFC module u...

Page 28: ...h to the OFF position 2 After approximately 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key...

Page 29: ...ark to pilot system to the standing pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption Wh...

Page 30: ...off key and the mode key at the same time 4 Reinsert 1 AAA battery 5 While still holding the on off key let go of ONLY the mode key 6 Index over to the flame graphic on the LCD screen to edit Use the...

Page 31: ...replace before fan operation The fan will continue to operate for approximately 12 minutes after the fireplace has been turned off Manual mode Fan s will operate at previous setting There is no delay...

Page 32: ...mum and maximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6...

Page 33: ...3 Factory Set Venturi Openings Fuel FRONT BACK Natural Gas 1 16 1 5 mm OPEN 1 16 1 5 mm OPEN Propane 3 8 9 5 mm OPEN 3 8 9 5 mm OPEN 12 2 1 1 Venturi Adjustment NOTE If soot is present on the glass c...

Page 34: ...Do not over tighten Pilot flame always on or will not extinguish Control system set to CPI mode Set control system to IPI mode Main burner flame will not light ON OFF rocker switch in OFF position Swi...

Page 35: ...nturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to section 12 2 1 Burner Venturi on page 33 Incorrect vent cap installation Adjust if necessar...

Page 36: ...uctions provided with installation Refer to Section 6 0 on page 15 Performed by Qualified Service Person Frequency Annually Action Examination of the vent system is required The flow of combustion and...

Page 37: ...ion device Visually check pilot light when in operation Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Check for faulty or incorrect wiring an...

Page 38: ...T IPI Gas Valve Propane 700 567 1 Valve Step Motor Propane 700 504 1 Proflame 2 IFC Board 700 652 15 in Flexible Gas Line Black 700 227f IFC Wire Harness Assembly 700 653 Flexible Gas Line Valve to Bu...

Page 39: ...f but not limited to improper chimney venting installation will also render this warranty void 7 This warranty does not cover installation and operational related problems such as environmental condit...

Reviews: