Page 11
COMBUSTION AIR REQUIREMENTS
This stove requires the use of outside air for combustion. A 2" diameter aluminum flex pipe 4 ft. long is included
with this stove to connect to the 2" collar located at the back.
WARNING: THE COMBUSTION AIR PIPE MUST BE PROPERLY CONNECTED AND TERMINATED TO THE OUTDOORS FOR
PROPER PERFORMANCE.
‚
Attach the 2" aluminum flex pipe over the collar at the back of the fireplace. Seal the connection.
‚
Do not crush or bend the aluminum flex pipe with too small a radius as this will block the flow of combustion air
and result in poor operation of the stove.
‚
Use of a hood for protection against wind and weather is recommended.
‚
An open mesh screen, no smaller than 1/4" x 1/4" should be placed over the outside air pipe opening to
prevent birds, rodents or insects entering the opening.
‚
Locate the outside air pipe termination (and hood) above maximum snow depth.
‚
Terminate the shortest distance possible. If the combustion air pipe length is over 10 ft., it is suggested to
increase to a 3" diameter pipe.
‚
The outside air must terminate below the exhaust outlet.
Summary of Contents for OLV-PC OLIVIA