Page 9
VENTING TERMINATION REQUIREMENTS:
MAXIMUM HORIZONTAL RUN: 9 FT.
MAXIMUM VERTICAL RUN: 36 FT.
Determine the best location for the vent termination cap. Items to consider:
‚
Distances from air inlets - Installation must comply with the requirements in this installation manual, the
requirements of the vent system you are using and local building codes.
‚
Prevailing winds - When terminating where prevailing winds would blow against the termination cap, sporadic
operation of this stove may result which may include excessive smoking inside the firebox.
‚
Location of adjacent structures - Installation must comply with the requirements in this installation manual,
the requirements of the vent system you are using and local building codes.
‚
Local code requirements - Check local building codes for additional requirements and/or restrictions
concerning installation of a corn / pellet burning stove.
Exhaust must terminate above the combustion air inlet.
Do not terminate vent in any enclosed or semi-enclosed area (i.e. Garage, Attic, Crawl space, etc.) or any area
which would build up a concentration of fumes.
Vent surface can get hot enough to cause burns if touched by children. Use non-combustible guards or shields if
necessary.
Combustion air must be connected to an outside source and not drawn from the indoor living environment,
garage, attics, crawl spaces and the like.
Summary of Contents for OLV-PC OLIVIA
Page 18: ......