18
INSTALLATION
Hussong Mfg. Co., Inc. Kozy Heat Fireplaces
#NDK-34-i R.1 July 2022
6.4
Co-linear to Co-axial Combined Venting
IMPORTANT: Maximum horizontal vent runs of 24” (609mm) require
a 1” (25mm) rise per 12” (305mm) run. Care should be taken when
installing the flexible vent pipes to avoid a tight bend that may cause
abrasion or damage to the flexible pipes.
After the co-linear to co-axial vent adapter, the co-axial pipe requires
a minimum of 1” (25mm) clearance to combustibles on all sides of the
rigid pipe.
•
Maximum horizontal run of 3” x 3” flexible pipe length: 24”
(610mm)
•
Minimum total combination of co-linear and co-axial vent pipe:
10’ (3.05m)
•
Maximum total combination of co-linear and co-axial vent pipe:
PROPANE: 40’ (12.19m)
NATURAL GAS: 40’ (12.19m)
Figure 6.2 Co-linear to Co-axial Venting
Table 6.4, Approved Vertical Vent Systems Co-Axial with Adapter
Vent Manufacturer
Vent Cap Part Number
American Metal Products (Ameri-Vent)
4DVC
BDM
DVR6-VCLP
DVR6-VCH
Simpson DuraVent
46DVA-VCH
46DVA-VC
46DVA-VCE
Metal Fab
4DVT
Olympia
VDV-VC04
Selkirk
4DT-VT
4DT-VC