3
. INSTALL THE VENT SYSTEM
NOTE: The 4” exhaust pipe and 3” combustion air intake pipe will extend 25 ft.. An optional extension kit (Part #510) is
available to extend the #815-CL kit up to a maximum of 40 ft.
A. Carefully extend the 3” combustion intake and 4” exhaust pipes and extension kit (if used) to
equal the total chimney length required.
B. 1. Slide the 3" intake pipe (end without the collar) onto the collar on the termination cap and
secure with 3 self-tapping screws (provided).
2. Place a bead of sealant around the inner edge of the 4" exhaust pipe (end without the collar)
and slide onto the corresponding collar on the termination cap. Secure with 3 self-tapping
screws (provided). Apply additional sealant around the joint to ensure a seal.
C. If an extension kit is being used, it must be connected as follows:
Exhaust extension: Apply a liberal bead of sealant (provided) around the exhaust adaptor
(male) extension pipe and slide into the female connector on the end of the 4” exhaust pipe
already attached to the chimney termination plates. Secure with 3 self-tapping screws,
(provided). To ensure an air-tight seal, additional sealant should be applied at the point of
connection.
Combustion intake extension: Apply a liberal bead of sealant (provided) around the male
end of the extension kit and slide into female end of the 3” combustion intake pipe attached
to the chimney termination plates. Secure with 3 self-tapping screws (provided). To ensure
an air-tight seal, additional sealant should be applied at the point of connection.
Figure D-2
PAGE 11
Summary of Contents for Jackson XL
Page 2: ......
Page 4: ......
Page 6: ......
Page 34: ......
Page 35: ...PAGE 30...
Page 36: ......
Page 37: ...PAGE 31...