Page 29
PROBLEM
CAUSE
SOLUTION
4.
Burner won't light.
Pilot not lit.
Relight pilot.
Regulator valve not turned “ON”.
Turn valve to "ON".
Rocker switch not turned “ON”. (Model CSK-335)
Depress switch.
Rocker switch wires not connected. (Model CSK-335)
Check wiring diagram, Figure Q-1,
to ensure that all wires are secure.
Generator wires loose at regulator terminals.
Reposition wire and tighten screws. See
Figures Q-1 & Q-2 for wiring instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinching of wires.
loosening to remove pinched wire.
Generator is not producing enough
Replace generator.
millivolts to operate burner.
Wall switch, remote control or thermostat not
Connect properly or disconnect
connected properly or turned to wrong setting. See
and use ON/OFF switch only.
Figures M-1 & M-2, page #18. (Model CSK-335)
5.
Burner won't stay lit.
Generator wires loose on
Reposition wires and tighten screws.
valve terminals.
See Figures Q-1 & Q-2 for wiring
instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinched wires.
loosening to remove pinched wire.
Generator is not producing enough
Check millivolt reading, replace
millivolts to sustain burner operation.
generator if necessary.
Refractory panels not positioned
Secure refractory panels with
against firebox.
high-temp sealant.
WIRING DIAGRAM
Model CSK-335-RF
Figure Q-2