
Page 17
L. COMPLETE THE INSTALLATION
1. THIS STEP SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER OR SERVICE TECHNICIAN:
A) Perform lighting and shutdown procedures as described on pages #19-#20 for Model #CSK-335 and pages #22-#23 for
Model #CSK-335-RF. This should be done prior to replacing the glass so that any necessary adjustments can be made
and proper operation and log position verified.
2. REPLACE THE GLASS. Refer also to Figure L-1.
WARNING: DO NOT OPERATE THIS FIREPLACE
WITH THE GLASS ASSEMBLY REMOVED,
CRACKED, OR BROKEN. Replacement of the glass
assembly should be done by a licensed or qualified
service person.
A. Align the 2 slots in the top of the glass assembly over the 2
tabs on the fireplace (at the top).
B. Place the glass assembly so it is flush with the front of the
fireplace front.
C. While holding the glass assembly, pull the latches out and
secure over the glass latch clips on the bottom of the glass
frame locking it in place.
Figure L-1
Left intentionally blank.
Summary of Contents for CSK-335
Page 33: ...Page 31 ...
Page 34: ...Page 32 ...