Heat Management Preparation Overview
SECTION 3
FRAMING
#BHM-38 & #BHM-38-BW
R.1 September 2021
22
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
3.7.2.1 Header Heat Shield Removal
The header heat shield can be removed to ease vented cavity and
Komfort Zone Kit installations.
The top standoff assembly must be installed for minimum distance
to header and a contact point for non-combustible material above
the fireplace. The back stand-offs must be installed. See
FIGURE
3.13
below.
1. Remove (4) screws securing the header heat shield to the stand-
off assembly.
2. Discard header heat shield.
3. Align the holes on the bottom of the stand-off assembly with the
holes on top of the fireplace. Secure with (4) screws total.
4. Remove and save screws securing the back stand-off
brackets. Form the back stand-off heat shields as shown.
Secure using screws previously removed and included in the
components packet.
Header heat shield
Stand-off assembly
Back stand-offs
FIGURE 3.13
Stand-off Assembly Installation